Home  >  Other Measuring & Analysing Instruments

High quality portable X-ray machine - XXQ/XXG/XXH series

High quality portable X-ray, 1. The controller works without noise, 2. Suitable with most brand of power generator - more info check here: http://www.buymeasuringtools.com/High-quality-portable-X-ray-machine-10217536/

Quick Brief

Place of Origin: Liaoning China (Mainland) Brand Name: HUARI Model Number: XXQ/XXG/XXH series

Product Features:

High quality portable X-ray

1. The controller works without noise

2. Suitable with most brand of power generator

Business Terms:

Port: DALIAN OR SHENYANG

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 500 Set/Sets per Year

Payment Terms: T/T

Contact Supplier
High quality portable X-ray machine
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: PLYWOOD CASE ,ONE CASE ,DIMENSION:1000*450*450mm

Delivery Detail: WITHIN 15 DAYS

Specifications and Product Details:

Portable NDT Equipment

Construction

Main technical parameters

Accessories

No.NmaeCount
1Power cable(3×2.5 cores, 10m)1
2Controller and tube head Connection

(10×2.5 cores 25m)

1
3Fuses 2A,10A,20A5 pieces every
4Ground cable(5m)1
5Power switch key2
6Door interlock cable plug1

The merit of HR-900 X-ray controller

1, Use IGBT working in high frequency instead of SCR. So the X-ray tube voltage and current keeps very stable even if the AC220 power supply voltage is violence changing in a wide range.

2, Has a higher power factor than controller with SCR.

3, Suitable with most brand of power generator

4, Has a real time clock and EEPROM in the controller that can remember operation record automaticaly. The controller can decide whether season is needed by this record.

The compare of controller with IGBT and controller with SCR

Ordinary controller with SCR.HR-900 controller with IGBT
Power factor0.23-0.450.66
Power factor constantNo, power factor decrease along with tube voltage decreaseYes
power consumptionHighLow
Generator (When There is not power source in the open air)Suitable with a few brand of power generator

Need adjust synchronization

Need large power generator, normal 5000W

Waveform of controller instability

Suitable with most brand of power generator

No need adjust synchronization

Need small power generator

Waveform of controller stability

Output tube voltage influenced by power fluctuationsLargeNo influenced
Both AC and DCNoYes
Number of adjustment potentiometer62
Limiting output current functionNoYes
Capacity of resisting impact of fault tubeweakBecause high voltage generator primary coil can automatically limit current. So capacity of resisting impact is strong. The controller almost is not influenced by high voltage fault and X-Ray tube fault.
Automatic season according to stopping timeNoYes
No power off until full cooling time. Force wind coolingNoYes
Directly shut off high voltage by keyNoYes

x ray equipment,ndt equipment,x ray flaw detector

High quality portable X-ray machine suppliers    High quality portable X-ray machine manufacturers