High Accuracy PH tester digital PH meter|PH pen - PH-C

PH tester|PH meter|PH pen, 1 Range: 0.0 to 14.0 pH, 2 Resolution:0.01 Ph - more info check here: http://www.buymeasuringtools.com/High-Accuracy-PH-tester-digital-PH-meter-PH-pen-10266408/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: 3WIN Model Number: PH-C

Product Features:

PH tester|PH meter|PH pen

1 Range: 0.0 to 14.0 pH

2 Resolution:0.01 Ph

Business Terms:

Minimum Order Quantity: 100 Piece/Pieces

Supply Ability: 50000 Piece/Pieces per Week

Payment Terms: T/T,Western Union

Contact Supplier
High Accuracy PH tester digital PH meter|PH pen
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard export packing

Delivery Detail: after 3 days after receiving payment

Specifications and Product Details:

PH tester|PH meter|PH pen (with ATC)

OPERATION MANUAL

SPECIFICATIONS

Range:0.0 to 14.0 pH

Resolution: 0.1 pH

Accuracy (@20°C/68°F):±0.1 pH

Typical EMC Deviation:±0.1 pH

Calibration: Manual, 1 point,

Temperature Compensation Automatic:0 to 50°C

Environment:0 to 50°C (32 to 122°F);

RH max 95%

Battery Type:4 x 1.5V alkaline

Battery Life :approx. 200 hours of use

Dimensions:152 x 30 x 21 mm

(5.9 x 1.2 x 0.8")

Weight:53 g

OPERATION

• Remove the protective cap. Do not be alarmed if white crystals

appear around the cap. This is normal with pH electrodes and

they dissolve when rinsed with water.

• Turn the meter on sliding the switch on the top.

• Immerse into solution up to the max immersion level. • Stir gently and wait until the display stabilizes. Readings are automatically compensated for temperature variations.

• After use, switch off pH meter, use the water clean the electrode and replace the protective cap.

DO NOT USE DISTILLED OR DEIONIZED WATER FOR STORAGE PURPOSES.

• Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

CALIBRATION

• Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution

• Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.9.

Calibration is now complete.

ALWAYS USE FRESH BUFFERS FOR CALIBRATION.

BATTERY REPLACEMENT

When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.

WARRANTY

These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase.

If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either dealer or our offices, and the repair will be effected free of charge.

High Accuracy PH tester digital PH meter|PH pen suppliers    High Accuracy PH tester digital PH meter|PH pen manufacturers