Home  >  Electrical Instruments  >  Other Electrical Instruments

High Accuracy Fluke 772 Milliamp Process Clamp Meter - F773

Fluke 772 Milliamp Process Clamp Meter, to 20.99 mA 0.2 % + 5 counts, Measured by clamp, 21.0 mA to 100.0 mA 1 % + 5 counts, 772 - more info check here: http://www.buymeasuringtools.com/High-Accuracy-Fluke-772-Milliamp-Process-Clamp-Meter-10043016/

Quick Brief

Place of Origin: Florida United States Brand Name: Fluke Model Number: F773 Display Type: Digital Only Measuring Range: DCV:24V Accuracy Class: 0.2%+2 counts Supply Voltage: 24V DC Operating Temperature: -10℃ to 50℃ Dimensions: 41.3mm*38mm*248mm Weight: 450g accuracy: 0.2%±2 counts

Product Features:

Fluke 772 Milliamp Process Clamp Meter

to 20.99 mA 0.2 % + 5 counts

Measured by clamp

21.0 mA to 100.0 mA 1 % + 5 counts

772

Business Terms:

Payment Terms: T/T,Western Union,MoneyGram

Contact Supplier
High Accuracy Fluke 772 Milliamp Process Clamp Meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

High Accuracy Fluke 772 Milliamp Process Clamp Meter

Use the Fluke 772 and 773 to:
• Measure 4 to 20 mA signals without ”breaking the
loop” just like the innovative and popular Fluke 771
Process Milliamp Clampmeter
• Source 4 to 20 mA signals for testing control
system I/O or I/Ps
• Simulate 4 to 20 mA signals for testing control
system I/O
• Measure 4 to 20 mA signals with in-circuit
measurement
• Simultaneously measure mA in-circuit with 24 V
loop power for powering and testing transmitters
• Source mA output signals in a linear ramp or 25 %
step output
– Automatically change the 4 to 20 mA output for
remote testing
• Power saving features, auto-off, backlight timeout
extend battery life

Fluke 773 features:
• DC voltage measurement to verify 24 V power
supplies or voltage I/O signals
• Source dc voltage to test input devices that accept
a 1 to 5 volt or 0 to 10 volt signal
• Scaled mA output provides a continuous mA signal
that corresponds to the 4 to 20 mA signal measured
by the mA clamp
– Output mA signal enables a logging DMM (289)
or other device to record the 4 to 20 mA signal
without breaking the loop
• mA in/out: simultaneously measure the mA signal
with the clamp and source a mA signal
– Apply a mA input signal to a device and measure
its’ 4 to 20 mA output on devices such as valves
or mA isolators
• Voltage output linear ramp or 25 % step output
– Automatically change the voltage output for
remote testing

Functions
mA measure
w/jaw
mA measure
In circuit mA source mA sim
Loop power
24 V
DCV source
0-10 V
DCV
measure
0-30 V
Scaled mA
output to mA
input mA in/out
771 •
772 • • • • •
773 • • • • • • • • •
Functional specifications
Function Resolution and range Accuracy Notes
771, 772, 773 mA measurement
0 to 20.99 mA 0.2 % + 5 counts
Measured by clamp
21.0 mA to 100.0 mA 1 % + 5 counts
772 and 773 mA measurement 0 to 24.00 mA 0.2 % + 2 counts Measured in series with test
jacks
772 and 773 mA source 0 to 24.00 mA 0.2 % + 2 counts Maximum mA drive: 24 mA into
1,000 ohms
772 and 773 mA simulate 0 to 24.00 mA 0.2 % + 2 counts Maximum voltage 50 V dc
773 Voltage source 0 to 10.00 V dc 0.2 % + 2 counts 2 mA maximum drive current
773 Voltage measure 0 to 30.00 V dc 0.2 % + 2 counts
General specifications 772 and 773 (see www.fluke.com/771 for more information on the Fluke 771 specifications)
Influence of earth’s field < 0.12 mA
Battery (4) 1.5 V, Alkaline, IEC LR6
Working hours 12 hours @ 12 mA source into 500 ohms
Size (HxWxL) 772, 773: 41.3 mm x 76 mm x 248 mm (1.625 in x 3 in x 9.75 in)
771: 59 mm x 38 mm x 212 mm, (2.32 in x 1.5 in x 8.35 in)
Weight 772, 773: 415 g (14 oz) 771: 260 g, (9.1 oz)
Operating temperature -10 °C to 50 ºC
Storage temperature -25 °C to 60 °C
Operating humidity < 90 % @ < 30 °C; < 75 % @ 30 ~55 °C
Operating altitude 0 ~ 2,000 m
Storage altitude None
IP rating IP 40
Vibration requirements Random 2 g, 5 Hz to 500 Hz
Drop test Passes 1 meter drop test (except the jaw)
EMI, RFI, EMC
Meets applicable requirements in EN61326-1 Note: For current
measurement w/jaw, add 1 mA to specification for EMC field strengths
of 1 V/m up to 3 V/m
Temperature coefficients 0.1(/°C x specified accuracy for temperature < 18 °C or > 28 °C)
Warranty Three-years, one-year on mA clamp assembly and cable