digital megohmmeter
1.equipped with strong measurement and data processing software .
Port: Wuhan/Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 40 Set/Sets per Day
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: carton
Delivery Detail: 20days after everything be confirmed
digital megohmmeter,earth resistance tester,ground resistance tester
It takes computer technology as kernel, LSI combined with digital circuit, equipped with strong measurement and data processing software , finish the insulation resistance, voltage tests, with stable features, easy to operate.
Products features
1.Automatic release the voltage.
2.Data transmission by USB
3. With function of back light, convenient to working in dark circumstance.
4. Test results displayed in bar pattern .
5. HV indicating symbol and red warning light.
6. Auto power off:
if without operation in 15 minutes after finished the test , it will auto power off.
7. Store 18 groups data.
8. Time setting: to test with in 15 minutes of the setting time
9.COMP measurement (comparing function)
10. Polarization index test
11. PI test can between any two time, auto test the resistance ratio according the setting.
12. Temperature :23±5°C
13. Relative humidity: 45~75%RH
Product parameters
1. Insulation resistance test
rated voltage | 500V | 1000V | 1500V | 2500V |
measurement range | 0.5MΩ ~ 5.0GΩ | 2MΩ ~ 10.0GΩ | 5MΩ ~ 20.0GΩ | 10MΩ ~ 100GΩ |
open-circuit voltage | DC500V+20%,-0% | DC1000V+20%,-0% | DC1500V+20%,-0% | DC2500V+20%, -0% |
rated measurement current | load: 500KΩ | load: 1MΩ | load: 1.5MΩ | load: 2.5MΩ |
1mA~1.2 mA | 1mA~1.2 mA | 1mA~1.2 mA | 1mA~1.2 mA | |
short circuit | <2.0mA | |||
accuracy | 100KΩ~100MΩ; ±(3%+5) 100MΩ~10GΩ; ±(5%+5) 10GΩ~100GΩ; ±(10%+5) |
Note: At any rated measurement voltage, if the measured voltage<10MΩ, the measurement time should be less than 10 seconds.
2. Voltage test
DC voltage | AC voltage | |
measurement range | ±30~±600V | 30~600V(50/60Hz) |
resolution | 1V | |
accuracy | ±(2%+5) | < 100V:±(2%+8) |
≥ 100V:±(2%+5) |
3. Display: LCD, the maximum reading is 9999.
4. Low battery warning.
5. Overrun indication “OL” symbol appear on the insulation resistance range.
6. Auto change the measurement range.
7. Unit display: functions, quantity of electricity display in symbol.
8. Service conditions: 0°C~ 40°C/relative humidity< 85%
9. Storage conditions:-20°C~ 60°C/ relative humidity< 90%
10. Dimension :202x155x94mm
11. Weight :2kg (includes the battery )
12. Current consumption: 600mA (maximum) ( usually keep it to be 20mA)