Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: tcontroller Model Number: HMWST-S1 Usage: Industrial Theory: Temperature Controller color: white type: HMWST-S1 power supply: 110V/220V

Product Features:

intelligent temperature controller

manual switch

socket

Plug in Digital Room Humidity Controller

Business Terms:

Port: shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 1000 Set/Sets per Month 1

Payment Terms: T/T

Contact Supplier
HMWST-S1 Plug in Digital Room Humidity Controller
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: box

Delivery Detail: 5 days

Specifications and Product Details:

HMWST-S1 type intelligent humidity controller introduction

The function of each button is clearly, through the relay hige to achieve automatic control, temperature controller will according to the changes and automatically shut off or start the control equipment.

1. Technical specifications:

Humidity measurement range:

0-99.9%RH

Sensor:

AM2301

Resolution:

0.1%RH

The control accuracy:

0.1%RH

Output type:

relay (contacts capacity of 250 V, 10 A),

Shell size:

87 mm x 135 mm x 45 mm

Working voltage:

AC85 ~ 242 V 50 Hz / 60 Hz

Types of control:
  • Humidifying-type
  • Dehumidification-type
  • Automatic humidifying dehumidification type

2. The parameters set operation:

3. Installation: instrument temperature must be held at around -5degree~ 65degree, the instrument must be placed in no damp and high pressure situation, and ventilation to easy to heat dissipation.

4. Wiring: put the device that need to control inserted in a socket, the power supply must match the manual of the instrument.

5. Parameter (the first group on the left, the right is the second group):

symbolsDescriptionrangeDefault value
rHHigh limit

0-99.9%RH

80%RH
rLLow limit70%RH
HCHumidifying/dehumidification switches00~7001

Note: HC humidifying/dehumidification switches data

00 = humidifying,01 = dehumidification

HC for other values are not output (right now this controller is used as the island-from mosquitoes)