HGQH-C speed transformer test device
1.capacity up to 7KVA
2.test 12 current transformer/3min
3.automatically switch
Port: ningbo/shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 3 Set/Sets per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: ship by wooden case
Delivery Detail: according to your requiry
HGQH-C speed test device of multiple-bit CT
Product Overview
HGQH-C speed test more than one bit transformer device is the company to adapt to the modern transformer check the rapid and accurate development of the characteristics of a new generation of transformer test equipment. The device consists of HGQA-C transformer calibrator, FY98 load current and voltage transformer box, control cabinet, current transformers, special test bench, and several other components. In maintaining the technical characteristics of the original premise, the rapid measurement of the current transformer quickly locate the test points, and the load box, the transformer turns ratio coverage of various aspects has been greatly improved.
Specifications
Environmental conditions | Temperature:5°C-40°C Humidity:Less than80%(25°C) Altitude:Less than 2500mm Power frequency:50Hz±0.5 Hz supply voltage:220V±5 V |
Measuring range | With the phase component (%): 0.0001~200.0 Rresolution:0.0001 Orthogonal component (sub):0.001~700.0 Resolution:0.001 Impedance (Ω):0.0001~20.0 Resolution:0.0001 Admittance (ms):0.0001~20.0 Resolution:0.0001 |
Basic errors | With the phase component: X=±(X*2%+Y*2%±2counts) Orthogonal components: X=±(X*2%+Y*2%±5 counts) “X”,“Y”--- shows the value of equipment "5 words" equipment quantization error Dial indicator:1.0degree Output current, output voltage:1.0 degree |
Scope of work | Current:(1%-149%)In(In=5A) (5%-149%)In(In=1A) Voltage:(5%-149%)Un(Un=100V,150V,100V/ ) (5%-149%)Un(Un=100V/3) |
Workload | Current: TO on the TXLess than 0.12Ω cosΦ=1 Voltage: a for x Less than 0.25VA (100V) |
Dimensions(cm) | Cross-platform body:1500(L)×780(W) ×1030(H) Vertical platform body: 670(L)×630(W) ×1570(H) |
Features:
1 The unit uses high-power programmable technology, comprehensive technical indicators in the country first, so that more accurate positioning of test points, capacity of up to 7KVA;
2 The current transformer installed in more than just measuring the speed has been a qualitative improvement, in 3 minutes to measure any change in the ratio of twelve current transformer;
3 The device configuration of the 1A, 5A of the standard current transformer, the current configuration of the load box 1A, 5A load value 2.5VA-80VA, voltage load box equipped with 100V, 100 / √ 3 load value from 1.25VA-158.75VA meet Various user requirements. Load me in the measurements can be automatically switched.