Product Description:
HF6000- series semi-automatic coagulation analyzer (IVD) has two types: HF6000-2 (dual-channel), and HF6000-4 (four-channel). The analyzer has a bench-top design and is ideal for small and medium-sized hospitals, laboratories, and clinical centers. The measurement principle is photoelectric magnetic beads method, i.e.: using photoelectric to test movements of magnetic beads, in order to determine the freezing point of the blood, and measure the time of blood freezing. This method is free from the interference of Jaundice, Hemolytic, Chyle and other samples. It is easy to operate and highly accurate, with low consumption of reagents; this equipment is highly valued by its cost-effectiveness.
Features:
l Semi-auto bench-top analyzer
l Automatically trigger a measurement with a connected auto-pipette after the sample is added, minimizing manual error
l Auto-save test result, can print real-time report and complete report
l Power-off protection (data can be kept 10 years)
l Good repetition, Repeat error: ±10%
Specification | Test Place | Test Item |
Dual-Channel | 2 | One |
Four-Channel | 4 | Four |
Main Technical Index:
l Methods and Technologies : Photoelectric magnetic beads method, free from the interference of Jaundice, Hemolytic, Chyle and other samples; One-key operating with two modes: 1. Four persons one item; 2. One person four items
l Test item: PT, APTT, TT, FIB; factors II, V, VII, VIII, IX, X, XI and XII; protein C; protein S; AT-III; venom time, etc.
l Pre-heating timer: Blink when the sample solution reaches estimated temperature
l Linearity: Wide linear range of fibrinogen test
l Reagent: Open reagent, low consumption of sample volume (150μL per test)
l Results: g/L, mg/DL, U/ML, s, %, %-INR, Ratio, Ratio-INR
l User Interface: User-friendly interface, man machine conversational operation
l Display: 5.7 inch blue screen with backlight, 320*240 graphic LCD display module; Real time display (year, month, day, week, hour, minute, second)
l Host Communication: Can be connected to computer via RS232 serial port for data exchange
l Storage: Can store data of 999 patients, and more than ten thousands test records
l Printers: Built-in thermal micro-printer, can print real-time report and complete report
l Dimensions/Weight: 490 mm(H) * 435 mm(W) * 280 mm(D); 6 kg
Power Supply: | AC220V±22V, 50Hz±1Hz | Input Power: | ≥170VA |
Operating Temperature: | 10°C-30°C | Relative Humidity: | 30-80% |
Measuring Precision: | ±10% | Channel Coherence: | ±10% |
Pre-heating Temperature: | 37°C±1°C | Pre-heating Time: | 15min-30min |