H726Multifunction Process Calibrator V/mA ohm RTD Thermocouple Hz - H726

*The Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator, *Loop Power Voltage: 24V, *Accuracy: 10 - more info check here: http://www.buymeasuringtools.com/H726Multifunction-Process-Calibrator-V-mA-ohm-RTD-Thermocouple-Hz-10103754/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: HY Model Number: H726 DC Voltage: 30V DC Current: 24mA Resistance: 4000Ω

Product Features:

*The Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator

*Loop Power Voltage: 24V

*Accuracy: 10

Business Terms:

Port: FOB shenzhen or guanzhou

Minimum Order Quantity: 2 Piece/Pieces

Supply Ability: 1000 Piece/Pieces per Day

Payment Terms: T/T,Western Union,paypal

Contact Supplier
H726Multifunction Process Calibrator V/mA ohm RTD Thermocouple Hz
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: 1pcs/color box/ 20pcx/CTN.

Delivery Detail: 5-7day

Specifications and Product Details:

FEATURES
In addition to the functions listed in Table 1,the calibrator also has the following characteristics:

1.A split-screen display. The upper display allows users to measure volts, current, and pressure only.The lower display allows the user to measure and source volts, current, pressure, resistance temperature detectors, thermocouples, frequency,and ohms.

2.A thermocouple (TC) input/output terminal with cold junction temperature compensation,ambient temperature can be set and calibrate within the menu function.

3.Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0% and 100% of the value. (In addition to the pressure output)

4.In the configuration menu can be set manually : Power off time for Instrument Backlight off time Screen Contrast Cold junction compensation ON/OFFHART resistence ON/OFF and ETC. You can also set the output amplitude and duty cycle for frequency manually in configuratiion menu.

5.Have calendar clock function,it can be calibrated in configuration menu.

6.It can store 8 sets of measurement and output data and call the showing at any time,all the settings and the functions of the last operation be auto-stored after power off.

Measure Accuracy:
FunctionMeasure SingalMeasure AccuracyOutput
0.000—30.000 V0.02%+3 counts (The upper display)
0.000—24.000 V0.02%+ 3 counts (The lower display)
0.000—90.000 mV0.01%+ 10 counts
DC Voltage-10.000 —80.000mV 0.01 % + 10 counts (use the thermocouple jack )
DC Current0.000—24.000 mA0.02%+ 4 counts(The upper display)
0.000—24.000 mA0.02%+ 4 counts(The lower display)
Resistance0.00— 400.00Ω0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire)
400.0—4000.0Ω0.5Ω (4 wire), 1Ω (2 wire and 3 wire)
Frequency0.010—20.000 kHz±4Hz
0.001—39.999.0Hz±0.01Hz
40.00 —99.99 Hz±0.05Hz
100.0 —500.0 Hz±0.5Hz
PressureDepends on the pressure moduleDepends on the pressure module
Output Accuracy:
OutputRangeAccuracy
DC Voltage0.000— 20.000 V0.02%+3 counts
0.000—90.000 m V0.01%+10 counts
-10.000 mV— 80.000 mV 0.01 % + 10 counts (use the thermocouple jack )
DC Current0.000—24.000 mA0.02%+ 4 counts
5.00 — 400.00 Ω0.15 Ω (Excitation current 0.15 to 0.5 mA), 0.1Ω (Excitation current 0.5 to 2 mA)
Resistance400.0 —4000.0 Ω0.5Ω(Excitation current 0.05 to 0.8 mA)
Frequency0.040—2.000 kHz±2Hz
2.000—4.000 kHz±8Hz
4.000—8.000 kHz±32Hz
8.000—10.000KHz±50Hz
Output Hz0.030—99.999Hz±0.005Hz
PressureDepends on the pressure moduleDepends on the pressure module

RTD and Thermocouple:
TypeMeasure AccuracyOutput Accuracy
PT-100 (385)0.3°C(4 wire), 0.5 °C(2 wire and 3 wire)0.3 °C
PT-100 (3926)0.3°C(4 wire), 0.5 °C(2 wire and 3 wire)0.3 °C
PT-100 (JIS)0.3°C(4 wire), 0.5 °C(2 wire and 3 wire)0.3 °C
PT-200 (385)0.8°C(4 wire), 1.6 °C(2 wire and 3 wire)0.8 °C
PT-500 (385)0.4°C(4 wire), 0.9 °C(2 wire and 3 wire)0.4 °C
PT-1000 (385)0.2°C(4 wire), 0.3 °C(2 wire and 3 wire)0.3 °C
Cu500.4°C(4 wire), 0.6 °C(2 wire and 3 wire)0.4 °C
Cu1000.4°C(4 wire), 0.6 °C(2 wire and 3 wire)0.4 °C
J:0.5 °C0.7 °C
K:0.8 °C0.8 °C
T:0.5 °C0.5 °C
E:0.5 °C0.5 °C
R:1.5 °C1.0 °C
S:1.5 °C1.5 °C
B:1.8 °C1.0 °C
N:0.8°C0.8 °C

Loop Power Voltage: 24V
Accuracy: 10%
Maximum Current: 24 mA, Short-circuit protection

H726Multifunction Process Calibrator V/mA ohm RTD Thermocouple Hz suppliers    H726Multifunction Process Calibrator V/mA ohm RTD Thermocouple Hz manufacturers