Home  >  Analyzers  >  Gas Analyzers

Gas Chromatograph - GC9790I

GC9790I Gas Chromatograph, 1.Power 90240Vac, 5060Hz, 2.0Kw, 2.Dynamic linear range >104, 3.Oven volume: 14.6 liters - more info check here: http://www.buymeasuringtools.com/Gas-Chromatograph-10233629/

Quick Brief

Place of Origin: Shandong China (Mainland) Brand Name: UNICOM-OPTICS or Neutral English Model Number: GC9790I

Product Features:

GC9790I Gas Chromatograph

1.Power 90240Vac, 5060Hz, 2.0Kw

2.Dynamic linear range >104

3.Oven volume: 14.6 liters

Business Terms:

Port: Qingdao port

Minimum Order Quantity: 1 Unit/Units

Supply Ability: 6,000.00 Unit/Units per Year

Payment Terms: T/T

Contact Supplier
Gas Chromatograph
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Carton

Delivery Detail: 9 Days

Specifications and Product Details:

GC9790I Gas Chromatograph

Capillary and packed column inlets, split and splitless, cool-on-column

Programmable oven, max 5 rates, 6 temperatures, up to 400ºC

Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD

Instrument control, method setup and run from keyboard entries

Rugged manual injection and manual pneumatics

Self-diagnosis of controls: thermal zone, flows, and detectors

Ready to use when product delivered and installed

Unbeatable price and service package

Guarantee timely and no-hassle service responding

Technical Parameter for GC9790Series

Dimension (cm)55(L)×48(W)×49(H)
Approximate weight (kg)50
Power90240Vac, 5060Hz, 2.0Kw
Environmental condition1050ºC, humidity <85%
Intuitive instrument controlPanel keypad input, 10 methods in memory
Display5 lines LED
Injection2 manual injectors, split/splitless, cool-on-column, valve injection. Max temperature 399ºC
Oven volume14.6liters
Column oven26(L)×15(W)×25(H)
Oven40ºC400ºC, ±0.1ºC. 5 rates, 6 temperature settings
No. of temperature zones5, inlet, oven, detector, aux 1, aux 2
Max temperature rise rate40ºC/min
PneumaticsManual control; Max pressure 10bar; Max column flow 50ml/min
Gas purificationsIn-line traps, O2, moistures, hydrocarbons, CO/CO2

FID Detector

Max temperature399ºC
ColumnCapillary or packed columns
Sensitivity<1×10-11g/s
Dynamic linear range>106
Base line rise<5×10-13A/30min
Noise5×10-14 A
Signal output1μV1000mV

FPD Detector

Max temperature399ºC
ColumnCapillary or packed columns
Sensitivity<1.4×10-12 g/s (P), <5×10-11 g/s (S)
Dynamic linear range>103 (P), >102(S)
Base line rise<4×10-10g/s /30min
Noise<4×10-10 g/s
Signal output1μV1000mV

TCD Detector

Max temperature399ºC
ColumnCapillary or packed columns
Sensitivity>2500mV ml/mg
Dynamic linear range>104
Base line rise<100μV/30min
Noise<20μV
Signal output1μV1000mV

ECD Detector

Max temperature399ºC
ColumnCapillary or packed columns
Sensitivity<1×10-13 g/ml
Dynamic linear range>104
Base line rise<50μV/30min
Noise<20μV
Signal output1μV1000mV

Detector: NPD

Max temperature399ºC
ColumnCapillary or packed columns
Sensitivity<5×10-13 g/s (N), <5×10-12 g/s (P)
Dynamic linear range>103
Base line rise<4×10-10g/s /30min
Noise<4×10-10 g/s
Signal output1μV1000mV

Specifications for GC9790Series

MODELSPECIFICATION

Dual packed column

GC9790FDual FID Detector
GC9790TTCD Detector
GC9790T-2TCD Detector, amplified board (high sensitivity)
GC9790PFPD Detector
GC9790EECD Detector
GC9790GDual FID Detector, dual FID amplified board (high sensitivity)
GC9790BDual FID Detector, TCD Detector
GC9790DFID Detector, FPD Detector
GC9790KDual FID Detector, ECD Detector
GC9790HTCD Detector, FPD Detector
GC9790L-3FID Detector, ECD Detector, FPD Detector

Capillary column inlet, Packed column inlet

GC9790JDual FID Detector
GC9790RDual FID Detector, NPD Detector
GC9790CDual FID Detector, dual FID amplified board
GC9790ADual FID Detector, TCD Detector
GC9790IFID Detector, FPD Detector
GC9790LDual FID Detector, ECD Detector
GC9790L-2FID Detector, ECD Detector, FPD Detector
GC9790QDual FID Detector, ECD Detector
GC9790NDual FID Detector, ECD Detector
Gas Chromatograph suppliers    Gas Chromatograph manufacturers