Home  >  Used Measuring & Analysing Instruments

Gas Chromatograph - GC9790II

GC9790II Gas Chromatograph, 1.Capillary and packed column inlets,, 2.split and splitless, cool-on-column - more info check here: http://www.buymeasuringtools.com/Gas-Chromatograph-10178110/

Quick Brief

Place of Origin: Shandong China (Mainland) Brand Name: UNICOM-OPTICS or Neutral English Model Number: GC9790II

Product Features:

GC9790II Gas Chromatograph

1.Capillary and packed column inlets,

2.split and splitless, cool-on-column

Business Terms:

Port: Qingdao port

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 6,000.00 Set/Sets per Year

Payment Terms: T/T

Contact Supplier
Gas Chromatograph
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Carton

Delivery Detail: 14 Days

Specifications and Product Details:

GC9790II Gas Chromatograph

Capillary and packed column inlets, split and splitless, cool-on-column

Programmable oven, 8 ramps temperature programming, 6 temperatures, up to 400º C

Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD

Instrument control, method setup and run from keyboard entries

Rugged manual injection and manual pneumatics

Self-diagnosis of controls: Thermal zone, flows, and detectors

Ready to use when product delivered and installed

Unbeatable price and service package

Guarantee timely and no-hassle service responding

Dual pneumatics

Dual packed column inlets
GC9790IIFDual FID Detector
GC9790IITTCD Detector
GC979IIT-2TCD Detector (new type)
GC9790IIPFPD Detector
GC9790IIEECD Detector
GC9790IIGDual FID Detector, dual amplified board
GC9790IIBDual FID Detector, TCD Detector
GC9790IIB-2Dual FID Detector, TCD Detector (new type)
GC9790IIDFID Detector, FPD Detector
GC9790IIKDual FID Detector, ECD Detector
GC9790IIHTCD Detector, FPD Detector
GC9790IIL-3Dual FID Detector, ECD Detector, FPD Detector

Packed column inlet, Capillary column inlet (split and splitless)

GC9790IIJDual FID Detector
GC9790IIRFID Detector, NPD Detector
GC9790IICDual FID Detector, dual FID amplified board
GC9790IIADual FID Detector, TCD Detector
GC9790IIA-2Dual FID Detector, TCD Detector (new type)
GC9790IIIFID Detector, FPD Detector
GC9790IILDual FID Detector, ECD Detector
GC9790IIL-2FID Detector, ECD Detector, FPD Detector
GC9790IIL-4FID Detector, ECD Detector, NPD Detector
GC9790IIL-5FID Detector, NPD Detector
GC9790IIL-6FID Detector, ECD Detector, NPD Detector
Dual Capillary column inlets (split and splitless)
GC9790IIQDual FID Detector
GC9790IINDual FID Detector, dual amplified board

Detector: FID

Detection limit≤3x10 -12 g/s
Sensitivity Mv.ml/mg[n-C16]
Noise≤3x10 -14 A
Drift≤5x10 -13 A/30min
Linear range≥10 6

Detector: TCD

Detection limit
Sensitivity Mv.ml/mg[n-C16]≥2500
Noise≤20μV
Drift≤100μV/30min
Linear range≥10 4

Detector: TCD(new type)

Detection limit
Sensitivity Mv.ml/mg[n-C16]≥8000
Noise≤20μV
Drift≤100μV/30min
Linear range≥10 4

Detector: ECD

Detection limit≤1x10 -13 g/ml
Sensitivity Mv.ml/mg[n-C16]
Noise≤20μV/30min
Drift≤50μV/30min
Linear range≥10 4

Detector: FPD

Detection limitMt≤1.4x10 -12 g/s(P), Mt≤5x10 -11 g/s(S) methyl parathion
Sensitivity Mv.ml/mg[n-C16]
Noise≤4x10 -10 A
Drift≤4x10 -10 A/30min
Linear range≥10 3 (P), ≥10 2 (S)

Detector: NPD

Detection limit
Sensitivity Mv.ml/mg[n-C16]Mt≤5x10 -13 g/s(N) Malathion, Mt≤1x10 -12 g/s(P) azobenzol
Noise≤4x10 -13 A/30min
Drift≤2x10 -12 A/30min
Linear range≥10 3

Gas Chromatograph suppliers    Gas Chromatograph manufacturers