Home  >  Analyzers  >  Other Analysis Instruments

GC9310 Gas Chromatograph - GC9310

large-screen LCD with real-time display of all parameters setting value and actual value - more info check here: http://www.buymeasuringtools.com/GC9310-Gas-Chromatograph-10034077/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: Jinghua Model Number: GC9310

Product Features:

large-screen LCD with real-time display of all parameters setting value and actual value

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 20 Set/Sets per Month

Payment Terms: T/T

Contact Supplier
GC9310 Gas Chromatograph
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Wooden box,800x650x570mm,G.W.:80Kg

Delivery Detail: 7-10days after payment

Specifications and Product Details:

GC9310 Gas Chromatograph

Standard Configuration

1) GC9310 gas chromatograph 1 set

2) Single packed column sampler set

3) Single capillary sampler 1 set

4) Single flame ionization detector 1 set

5) Power cable 1 pc

6) User’s manual 1pc

7) Certificate of quality checking 1 pc

8) Packing list 1pc


Optional Accessories

1) Chromatograph workstation

2) TCD (with power)

3) FPD

4) NPD

5) FID

6) Gas generator of nitrogen, hydrogen,

7) Column

8) The other consumables


Packing Information:

Wooden Box 800x650x570mm

G.W.:80kg


















































Temperature

Control


Temperature Range


5°C~399°C(Incremental 1°C)


Temperature Accuracy


Better than±0.1°C(200°C)


Temperature-programmed


magnification


10


Temperature-programmed


rate set


0.1°C~40°C/min(Incremental 1°C)(200°C)


Magnification temperature time


0~655min(Incremental 1min)


Temperature
object


Column box, thermal
conductivity, detector, injector, capillary injector


TCD


Sensitivity


≥3000mv.ml/mg


Baseline noise


≤20μv


Baseline draft


≤50μv/30min


Gas flow rate stability


≤1%


FID


Detection limit


≤8×10-12g/s


Baseline noise


≤5×10-14A


Baseline draft


≤2×10-13A/30min


Injector,

Detector

Thermal conductivity

Temperature Indicators


Temperature Range


5°C~399°C(Incremental 1°C)


Temperature Accuracy


Better than ±0.1°C(200°C)


















































Temperature

Control


Temperature Range


5°C~399°C(Incremental 1°C)


Temperature Accuracy


Better than±0.1°C(200°C)


Temperature-programmed


magnification


10


Temperature-programmed


rate set


0.1°C~40°C/min(Incremental 1°C)(200°C)


Magnification temperature time


0~655min(Incremental 1min)


Temperature
object


Column box, thermal
conductivity, detector, injector, capillary injector


TCD


Sensitivity


≥3000mv.ml/mg


Baseline noise


≤20μv


Baseline draft


≤50μv/30min


Gas flow rate stability


≤1%


FID


Detection limit


≤8×10-12g/s


Baseline noise


≤5×10-14A


Baseline draft


≤2×10-13A/30min


Injector,

Detector

Thermal conductivity

Temperature Indicators


Temperature Range


5°C~399°C(Incremental 1°C)


Temperature Accuracy


Better than ±0.1°C(200°C)

GC9310 Gas Chromatograph suppliers    GC9310 Gas Chromatograph manufacturers