I/P:4 to 20mA output from Oxygen / Toxic / Combustible Gas Transmitters,Range:0 to 9999 In Unit P.P.M. OR % L.E.L. OR % VOL.
Port: Mumbai.
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 200 Unit/Units per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: Standard Thermocol & cartoon packing. For Export order wooden packing are available on request.
Delivery Detail: 1 Week.
Oxygen Monitor Weatherproof
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATIONS: | ||
Input | 4 to 20mA output from Oxygen / Toxic / Combustible Gas Transmitters | |
Range | 0 to 9999 In Unit P.P.M. OR % L.E.L. OR % VOL. programmable by user | |
Resolution | 1 / 0.1 Resolution programmable by user | |
Accuracy | ± 1% of full scale value | |
Dual Display | 2 X 4 digits of 13mm (H) Red LED display for Gas concentrations for CH-1 and CH-2 | |
LED Indication | 3mm, 7 LED indication for AL1, AL2,TD1, TD2, PRG, TX, RX | |
Set Point | One independent alarm set point for both CH-1 & CH-2 with programmable latch & non latch facility | |
Control Action | LO / HI, HI / LO, LO / Very LO & HI / Very HI, Programmable by user | |
Hystersis | 0 to 100 Counts, individual setting for Alarm Relay-1 & Alarm Relay-2, programmable by user | |
Time Delay | Independent Programmable 0 to 9999 Sec for Alarm Relay-1 & Alarm Relay-2 | |
Relay Output | Alarm Relay-1 operates for CH-1 & Alarm Relay-2 operates for CH-2 | |
Relay Contact type | 1 NO/C/NC Relay contact rated 230VAC/5A each for Alarm Relay-1 (CH-1) & Alarm Relay-2 (CH-2) | |
Settings | Setting by 4 keys on front panel i.e. "SET / NEXT", "UP", "DOWN" & "BACK" | |
Monitoring | i) By display : Sensor break/ open shows "oPEn", under range shows "Undr" & over range shows "ouEr" ii) By Retransmission current : Upscale current : 21mA, Down scale current : 3mA, selectable | |
Supply Voltage | 230VAC ± 10% OR 110VAC ± 10% OR 24 VDC | |
Cable | 1.5 sq. mm 3 Core OR 2 Core, Flexible OR Armored shielded cable | |
Operating Temperature | 0 to 50°C ± 5%, Relative Humidity: Below 95% non Condensing | |
Enclosure Details | GM - 2200 - WP (Weatherproof) | GM - 2200 - FLP (Flameproof) |
Protection Class | IP-65 | IP-65 for Gas Gr.IIA & IIB, CCOE & CMRI approved |
Cabinet Material | Polycarbonate, gray colour | Cast Aluminum alloy, LM-6 / C.I. Enclosure |
Cable Entry | Thermoplastic cable gland (IP-68) with clamping range of 2.5 to 6.5mm | Double compression cable gland (Ex-proof), ¾ ET-type |
Dimension | 250 mm(H) x 290mm(W) x 145 mm(D) | 350 mm(H) x 290 mm(W) x 170 mm(D) |
Mounting | Wall Mounting / Stand Mounting | Wall Mounting / Stand Mounting |
Weight | Approx 2.5kg | Approx 5.0kg |
Optional | a) Isolated RS-485 Serial port with MODBUS RTU protocol output b) SMARTLOG / SCADA SOFTWARE for online graph & data report for safety Audit c) Flame Proof or Non Flame Proof Industrial Hooter, Hooter cum Flasher, Chart recorder, Cables, PC Software, Gas Transmitters, 24 VDC power supply, Gas calibration kit d) Optional programmable linear 4-20mA / 20-4 mA O/P with respect to Gas concentration for CH-1& CH-2 |