Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: BEATOP Model Number: GA-9300S LPSA Measuring Range: 0.1-716um Repeatability: <1%(Deviation of D50 in CRM) Accuracy: <1%(Deviation of D50 in CRM) Principle: Mie Scattering Theory Laser source: import semi-conductor laser Operating System: Windows XP/ Window 7 Connecting Port: RS232 or USB Photodetector: 76pcs , forward 68, lateral 8 Ultrasonic Power: 50W Outer dimension: 760*300*300mm

Product Features:

Auto alignment

Water or organic solvent as medium

Business Terms:

Port: Zhuhai

Minimum Order Quantity: 1 Set/Sets n/a

Supply Ability: 150 Set/Sets per Month n/a

Payment Terms: L/C,T/T

Contact Supplier
GA-9300S Intelligent Laser Particle Counter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Seaworthy packing

Delivery Detail: 1 month after order confirmation

Specifications and Product Details:

GA-9300S Laser Particle Size Analyzer

GA-9300S is upgrade model of GA-9300H.In addition to all features of GA-9300H, it has many automatic features including light parth self-alignment, automatic sample feeding, automatic water supply and drainage, ultrasonic timer and water flow rate controller, etc. Functional software make it user-friendly. Imported semi-conductor laser provides larger power, longer service life as well as better monochromaticity; specially designed large-sized high-sensitivity photoelectric detector is manufactured by technique of large scale integrated circuit; sample feeding mode includes small sample cell and flow cell; full Mie theory is applied and data is processed by several distribution models; integrated circuit with highly precise data transmition and processing improves accuracy, repeatability and test speed.

Technical Specification

  1. Size Range: 0.1-716um
  2. Repeatability: <1%(Deviation of D50 in CRM)
  3. Accuracy: <1%(Deviation of D50 in CRM)
  4. Principle: Mie Scattering Theory
  5. Laser source: import semi-conductor laser
  6. Operating System: Windows XP /Windows 7
  7. Connecting Port: RS232 or USB
  8. Photodetector: 76pcs , forward 68, lateral 8
  9. Ultrasonic Power: 50W

10. Tank Capacity: 500ml

11. Circulating Flow Rate: 500-2500ml/min

12. Agitator Speed: 500-2500rpm

13. Small cell capacity: 20ml

14. Small cell agitator speed: 120rpm

15. Voltage: 220V, 50/60Hz

16. Outer dimension: 760×300×300mm

Application

  1. Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite, clay, garnet, vermiculite, Titanium white power, etc.
  2. Metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.
  3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, pigment, oil exploration, geological analysis, river silt and electronic particle, etc.

Features

  1. Advanced forming technique makes it compact in structure, graceful in appearance thus convenient in use and maintenance. Effective anti-interference technology improves electrical stability and reduces fault rate.
  2. Two sample feeding modes: small cell and flow cell (automatic circulating & dispersing system (ACDS) selectable for user with easy replacement.
  3. Mie scattering and Fraunhoffer diffraction theories are applied in data processing, both includes R-R distribution and random distribution for selection.
  4. Inside self-alignment system controlled by computer will search for lens focus automatically to improve accuracy; separate ACDS make sample preparation more convenient.
  5. Specially designed light receiver array with 76 detectors improves resolving power. User-friendly interface of test software make operation easy including results save, locating, comparison, merging, editing, delete, help, etc.
  1. Six report forms in Chinese and English including cumulative particle size distribution data and graph, frequency particle size distribution data, histogram and typical particle diameter range such as D3, D10, D25,D50, D75, D84, D90, D97, D98, etc. Layout, color, and font of the report are editable.

Feature I - Powerful Software

  1. Test software can operate smoothly in any Windows TM system with user-friendly interface.
  2. Processes data with full Mie scattering theory. RI's of varied samples and mediums are available to ensure accuracy.
  3. Save, find, delete, merger, compare test results before print out in multiple forms. Analysis processing in Excel is available.
  4. Varied test data and figures are obtainable in one window in serial test, easy for the comparison of accuracy and repeatability.
  5. Real-time monitoring can single out and delete abnormal test to make results reliable.
  6. Full Mie scattering theory on data processing.
  7. Integration of test and state: integrate test steps in one window to make it convenient and efficient.
  8. Automatic adjustment on light path by program: it will examine and correct light beam constantly to make it illuminate center of detector all along.
  9. Test report will be processed and printed in Word, Excel and WordPad, etc.

Feature II Precise 3-D Self-Alignment System
Performance

Advantage

  1. Constant alignment: in each test light beam will illuminate center of the detector to improve accuracy.
  2. Free replacement: Light beam stay in alignment even during replacement of small sample cell and flow cell.
  3. Self-alignment: in case of light path deviation due to slight deformation of instrument (caused by installational location, vibration, heat expansion and cold contraction), system will correct it automatically to maintain accuracy.

Feature III GA-800 Auto Circu. & Disper.System

  1. Sample preparation is of significance for test results. Before test, sample will be dispersed until stable and homogeneous in proper concentration without sedimentation during circulation. BT-800 incorporates all of these capabilities.
  2. Ultrasonic System (50W): During dispersing, shock wave of ultrasonic act on particles through water to disperse them fully without breaking. Optimal test condition is available under Precise Timing Function.
  3. Circulating pump: Centrifugal assembly is completely made of stainless steel, no pollution to sample. Pump blades will fully agitate sample to make it homogeneous. Adjustable flow rate is suitable for varied particle size or sample with varied density.
  4. Highly automatic: Automatic controllers on liquid level and water supply and drainage as well as connection to water tap result in automatic water supply, flush and drainage.
GA-9300S Intelligent Laser Particle Counter suppliers    GA-9300S Intelligent Laser Particle Counter manufacturers