calorimetry
1.24 Patents.
2.Method:Isoperibol
2.Strong environmental adaptability
3.Fast test speed: Analysis Time <13min
Port: Main ports in China
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 10 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Plywood case.
Delivery Detail: Within three weeks after the order
calorimetry
Applicable standards
ASTM D 5865-2007a Standard test method for gross calorific value of coal and coke.
GB/T213-2008 Determination of calorfic value of coal
Standard layout: SDC311 mainframe, Dedicated water tank, Lenovo computer, Laser printer
Technical Parameter:
Single Complete Testing Duration | <13 min | Precision | RSD≤0.1% |
Stability | Heat Capacity Variation in 3 months≤0.20 % | Ambient Temperature | The test results confirm to demands when temperature during (10-30)oC |
Accuracy | The mean value and standard value deviation is less than 50J/g after 5 caloric value tests of benzoic acid. | Max Test Range | 42000J/g |
Temperature Resolution | 0.0001 K | Sample Weight | 0.5-1.5g |
the Water Weight of External Barrel | 40kg | New type of Oxygen Bomb | Yes |
Oxygen Bomb Identification | Automatic | CAN Bus Interface | Yes |
Self-diagnostic Function | Yes | Complete Appliance Crust Shaped | Yes |
Max Power | 1.5kW | Voltage | AC220±10% 50Hz±1Hz |
Mainframe Size | 432×560×393mm | Net Weight | 60kg |
Main Features:
1.High Adaptability to Environment
Jacket and jacket lid equipped with water circulation device and temperature control system, which can make sure the water temperature of each part of the jacket be consensus and constant, thus the test results will not be affected even the room temperature fluctuates up to 10°C.
Unique design of inverter which can purify and stabilize the power supply, ensures the calorimeter will not be affected by the fluctuation of power voltage (From 160V to 240V) and frequency.
2.High Precision and Accuracy of Test Results
Buck water will be drained to water tank directly after finishing the test, so the inlet and outlet of bucket water will not affect the jacket water.
Constant volumetric tank with temperature control device makes sure water volume and temperature of each test are exactly the same.
Temperature measured by PT100 platinum resistance to the nearest 0.001K
Equipped with high quality water purification device, the water quality of each test is guaranteed.
3.High Efficiency and Automation
With bomb identifier, up to four bombs can be recognized, operators can prepare other bombs while testing thus improvement gained in efficiency and operating time.
Automatic oxygen filler equipped, oxygen filling by one press.
Automatic controlling of water volume, filling, heating, empting and jacket water circulation.
Automatic sample ignition.
Automatic temperature measurement and result calculation.
4. Easy to Operate, Handle and Maintain