Home  >  Testing Equipment

Fully automatic Calorimetry SDC313 - SDC313

calorimetry, 1.24 Patents., 2.Method:Isoperibol, 2.Strong environmental adaptability, 3.Fast test speed: Analysis Time <13min - more info check here: http://www.buymeasuringtools.com/Fully-automatic-Calorimetry-SDC313-10325246/

Quick Brief

Place of Origin: Hunan China (Mainland) Brand Name: Sundy Model Number: SDC313 Power: Electronic Usage: Auto Testing Machine Analysis Purpose: Calorific value Applications: Coal, coke,petroleum, cement blac... Standards: ASTM D5865-2010 and ISO 1928 Certification: ISO 9001

Product Features:

calorimetry

1.24 Patents.

2.Method:Isoperibol

2.Strong environmental adaptability

3.Fast test speed: Analysis Time <13min

Business Terms:

Port: Main ports in China

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 10 Set/Sets per Month

Payment Terms: L/C,T/T

Contact Supplier
Fully automatic Calorimetry SDC313
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Plywood case.

Delivery Detail: Within three weeks after the order

Specifications and Product Details:

calorimetry

Applicable standards

ASTM D 5865-2007a Standard test method for gross calorific value of coal and coke.

GB/T213-2008 Determination of calorfic value of coal

Standard layout: SDC311 mainframe, Dedicated water tank, Lenovo computer, Laser printer

Technical Parameter:

Single Complete Testing Duration<13 minPrecisionRSD≤0.1%
StabilityHeat Capacity Variation in 3 months≤0.20 %Ambient TemperatureThe test results confirm to demands when temperature during

(10-30)oC

AccuracyThe mean value and standard value deviation is less than 50J/g after 5 caloric value tests of benzoic acid.Max Test Range42000J/g
Temperature Resolution0.0001 KSample Weight0.5-1.5g
the Water Weight of External Barrel40kgNew type of Oxygen BombYes
Oxygen Bomb IdentificationAutomaticCAN Bus InterfaceYes
Self-diagnostic FunctionYesComplete Appliance Crust ShapedYes
Max Power1.5kWVoltageAC220±10% 50Hz±1Hz
Mainframe Size432×560×393mmNet Weight60kg

Main Features:

1.High Adaptability to Environment

Jacket and jacket lid equipped with water circulation device and temperature control system, which can make sure the water temperature of each part of the jacket be consensus and constant, thus the test results will not be affected even the room temperature fluctuates up to 10°C.

Unique design of inverter which can purify and stabilize the power supply, ensures the calorimeter will not be affected by the fluctuation of power voltage (From 160V to 240V) and frequency.

2.High Precision and Accuracy of Test Results

Buck water will be drained to water tank directly after finishing the test, so the inlet and outlet of bucket water will not affect the jacket water.

Constant volumetric tank with temperature control device makes sure water volume and temperature of each test are exactly the same.

Temperature measured by PT100 platinum resistance to the nearest 0.001K

Equipped with high quality water purification device, the water quality of each test is guaranteed.

3.High Efficiency and Automation

With bomb identifier, up to four bombs can be recognized, operators can prepare other bombs while testing thus improvement gained in efficiency and operating time.

Automatic oxygen filler equipped, oxygen filling by one press.

Automatic controlling of water volume, filling, heating, empting and jacket water circulation.

Automatic sample ignition.

Automatic temperature measurement and result calculation.

4. Easy to Operate, Handle and Maintain

Fully automatic Calorimetry SDC313 suppliers    Fully automatic Calorimetry SDC313 manufacturers