This instrument is used for analyzing & measuring the content & concentration of elements (K, Na, Li, Ca, Ba).
Port: Beijing,Shanghai,Guangdong
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 100 Piece/Pieces per Week
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Supplier
Main Products: UV-Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, Automatic Polarimeter, Whiteness Meter, Turbidity Meter, Tintometer, Colorimeter, Gloss Meter, PH/DDS/TDS Meter, Abbe Refractometer, etc.
Application:
This instrument is used for analyzing & measuring the content & concentration of elements (K, Na, Li, Ca, Ba). It can be widely applied to agriculture (soil, fertilizer, tobacoo), industry (cement, glass, ceramics, mineral or ore powder, fireproof material), food (wine, water), laboratory, clinical experiments and pathology research (serum, urine, plasma), etc.
Characteristics:
# With 5 channels and be able to detect K, Na, Li, Ca, Ba 5 elements. With K, Na, Li, Ca, Ba five filters, which can detect three kinds of elements, show three kinds of element content simultaneous.
# Operates on propane, butane or liquefied petroleum gas.
# Standard accessories: air-compressor, PC software or micro-printer.
# LCD Display, touch panel with numeric keypad.
# Single point calibration & calibration curve can be saved.
# RS232 interface, external computer or printer. With a mist separator.
Model: AP1500
Measurement Range:
K: 0-100ppm;
Na: 0-100ppm;
Li: 0-100ppm;
Ca: 0-1000ppm;
Ba: 0-3000ppm;
Measurement Limit:
K: 0.01ppm
Na: 0.01ppm
Li: 0.025ppm
Ca: 0.1ppm
Ba: 10ppm
Drift: ≤ 3% (after 30 minutes when the instrument stability)
Sample Rate: 4 ~ 6ml/min
Linearity: Better than the best results of the intermediate value of 2% (single-point CAL)
Response Time: less than 8s
Time Stability: Less than 15 seconds (when the sample was taken after the flame).
Calibration Methods: Straight line, broken line, secondary fitting.
Size & Weight: 530X510X580mm & 27kg
Model: AP1400
Measurement Range:
K: 0-100ppm;
Na: 0-100ppm;
Li: 0-100ppm;
Ca: 0-1000ppm;
Measurement Limit:
K: 0.01ppm
Na: 0.01ppm
Li: 0.025ppm
Ca: 0.1ppm
Drift: ≤ 3% (after 30 minutes when the instrument stability)
Sample Rate: 4 ~ 6ml/min
Linearity: Better than the best results of the intermediate value of 2% (single-point CAL)
Response Time: less than 8s
Time Stability: Less than 15 seconds (when the sample was taken after the flame).
Calibration Methods: Straight line, broken line, secondary fitting.
Size & Weight: 530X510X580mm & 27kg