ISO9001 ceritificate
fast, accurate & steady
high environment adaptability
easy to operate
low cost but reliable
Port: China main ports
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 10 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Plywood case
Delivery Detail: within 3 weeks after the order
SDC313 Calorimeter
Applicable Scope:
SDC Series Calorimeters are applicable to measure the calorific value of coal, coke, petroleum, cement black meal and other combustibles.
Conformance with standards
ASTM D 5865-2007a Standard Test Method for Gross Calorific Value of Coal and Coke
GB/T213-2008 Determination of calorific value of coal
Standard layout: SDC313 Mainframe, Lenovo computer, laser printer
Technical parameter :
Single Complete Testing Duration | <13 min | Precision | RSD≤0.1% |
Stability | Heat Capacity Variation in 3 months≤0.20 % | Ambient Temperature | The test results confirm to demands when temperature during(10oC-30oC) |
Accuracy | The mean value and standard value deviation is less than 50J/g after 5 caloric value tests of benzoic acid. | Max Test Range | 42000J/g |
Temperature Resolution | 0.0001 K | Sample Weight | 0.5-1.5g |
the Water Weight of External Barrel | 40kg | New type of Oxygen Bomb | Yes |
Oxygen Bomb Identification | Automatic | CAN Bus Interface | Yes |
Self-diagnostic Function | Yes | Complete Appliance Crust Shaped | Yes |
Max Power | 1.5kW | Voltage | AC220±10% 50Hz±1Hz |
Mainframe Size | 432×560×393mm | Net Weight | 60kg |
Main Features:
1. All measured data are real and reliable. Software correction is no need.
2. Highly automated instrument; can automatically recognize oxygen bomb, fix the quality of water, control temperature and carry out the test.
3. Strong adaptive capacity to environment; the testing results will not be affected by the fluctuation of the ambient temperature.
4. The isothermal points with helix tube technology (Patent number 200610031417.X,200610031414.6) realized temperature consensus of every part of the external barrel and barrelhead quickly, temperature of any fixed point can exactly represent that of the external barrel and barrelhead, making sure the test results are accurate.
5. The application of power contravariance and purification technology makes sure the instrument will not be affected by large variation of power voltage or power frequency.
6. Simple installation and debugging, easy to control.
7. Multiple controls by one computer and the inter-testing activity will not mutually affect.
8. Dada processing works in parallel with testing; easy for the users to look up test data.
9. Networking and the balance interlocking are possible.