Three input channel INA, INB, INC, Three programmable output channel OUTA, OUTB, OUTC, RS485 communication
1 Input specification(modularization,three channels
Humiture sensor input Switching value (dry contact) input
2 Measuring range
Temperature: -40C~+85C Humidity: 0%RH~99%RH
3 Intrinsic error
Temperature:±0.5C Humidity:±3%(RH10%~RH90%RH), total range ±5%RH
4 Resolution: Temperature 0.1C, Humidity:1%RH
5 Automatic inspection interval:1~10s
6 Control method: On-off control (return difference can be set)
7 Operational power supply: 85~264VAC/50~60Hz, consumption:10VA;
8 Operational environment: places free of gas corruption with temperature of 0C~50C, and relative humidity≤85%RH