automobile exhaust gas analyzer, vehicle emission gas analyzer, emission gas analyzer, auto test gas analyzer, residual gas anal
Port: SHANGHAI
Minimum Order Quantity: 1 Piece/Pieces
Payment Terms: L/C,T/T,Western Union
Contact Supplier
automobile exhaust gas analyzer, vehicle emission gas analyzer, emission gas analyzer, auto test gas analyzer, residual gas analyzer, exhaust gas analyzer, automotive emission analyzer, auto emission tester
SV-500A Exhaust AnalyzerBrief introduction:
Functional feature:
High accuracy, automatic calibration, automatic check automatically HC residual checks to wash with pipeline system Automatic Cleaning sampling pipeline, a variety of alternative measurement methods, environmental temperature, humidity, atmospheric pressure, speed, temperature and other parameters, GB/T 18285-2005 meet on the ASM-mode test equipment requirements.
Use:
Apply to petrol vehicles steady loading conditions (ASM) emissions testing system.
Apply to safety inspection station, test station and environmental inspection stations and other stations.
Apply to all types of auto repair shop.
Apply to motor vehicles for factory new test, detection application.
Apply to scientific research institutions, colleges and universities to conduct research using laboratory.
Main technical feature:
1. Measurement Range:CO:0-15%; CO2:0-20%;
HC:0-10000ppm; O2:0-25%;
NO:0-5000ppm;
Petrol temperature :0ºC-150ºC;
Engine speed:0-20000rpm;
2. Zero point floating: CO:±0.06%; CO2:±0.2%;
HC:±20ppm; O2:±0.2%;
NO:±20ppm;
3.Resolution:CO:0.01%; CO2:0.1%;
HC:1ppm; O2:0.01%;
NO:1ppm;
Petrol temperature:0.1ºC;
Engine speed:1rpm;
4. Indicated error: CO:±3%(0~10.00×10-2(%)vol)±5%(10.01-15.00×10-2(%)vol)
CO2:±3% (0~16.00×10-2%)vol)±5%(16.01-20.00×10-2(%)vol);
HC:±3%(0~2000×10-6(ppm)vol)±5% (2001~5000×10-6(ppm)vol)±10%(5001~9999×10-6(ppm)vol);
O2:±5%;
NO:±4%(0~4000×10-6(ppm)vol)±8%(4000~5000×10-6(ppm)vol);
Petrol temperature:±2ºC(absolute error);
Engine speed:±1.0%(relative error);
5. Display method: LCD large screen display;
6. Method of sample taking: Double sampling probe, respectively for petrol and diesel exhaust emissions;
7. Main functions: Built-in printer, RS232 interface, configurable plates, can store 500 measurements group.