1. Maximum Test Hardness: 70 HRC
2. Battery Operation Period: Typically 10 hours
3. Brand Name: Equostat 3
The Equostat 3 was developed for accurate, rapid and reproducible metal hardness testing. It features excellent sensitivity through small penetration of a few µm and is therefore particularly suited for testing metal hardness of surface layers on scratch-sensitive and polished parts or on thin parts, profiles and pipes with a wall thickness that is below 2 mm (0.08). The Equostat 3 works well in outdoor, factory and lab environments. It has only very few requirements on test piece geometries. The Equostat 3 probe can be connected directly to a laptop or a PC. Alternatively, the probe plugs into the Equotip 3 indicating device to combine the Rockwell principle of Equostat with the Leeb rebound principle of Equotip 3 to become the most versatile hardness tester. Live user guidance dialogs enable the user to obtain very accurate and highly reproducible measurements.
Features
• Accurate, rapid and reproducible metal hardness readings
• Measurements are independent of the material and sample dimensions
• Testing range from very soft (aluminum) up to very hard materials (case-hardened steel)
• Measurement in HRC, integrated conversions to HV, HB, HRA, HRB, HR15N, Rm possible
• Transfer of up to ~100,000 stored readings from the Equotip 3 indicating device to a PC using Equolink 3
• Small test load yields small penetrations of only a few μm
• The Equostat 3 probe can be used in either a clamp or freehand
• In addition to the Equostat 3 probe, all the impact devices of the Equotip metal hardness tester can be used to also conduct rebound hardness testing with the same indicating device
Applications
• Precise metal hardness testing of very soft materials through to very hard materials
• Thin parts, profiles and pipes of a wall thickness ≤ 2 mm, sheets, coiled metal, as well as parts as thin as 0.2 mm (0.008), depending on the hardness level
• Testing on scratch-sensitive or polished surfaces
• Metal hardness testing of heat-affected zones near welding seams
Proceq offers accessories such as a measuring clamp or several support feet adapt to freehand hardness measurements on various test piece geometries
Standardization
• DIN 50157 (2007)
• ISO 18265 (2003)
• ASTM B724
• ASTM E140 (2007)
• DGZfP Guideline MC 1 (2008)
• VDI / VDE Guideline 2616 Paper 1 (2010)
Warranty
• Standard 2-year limited warranty on electronic parts
• Optional extended warranty periods up to 3 additional years
Technical Data
Measuring Range (DIN) | 0-100 µm; 19-70 HRC; 19-70 HMMRC; 67-638 HB; 35-950 HV; 60-86 HRA; 29-107 HRB; 225-2250 MPa (N/mm2); 69-94 HR15N; 88-96 HR15T |
Resolution | 0.1 µm; 0.1 HRA; 0.1 HRB; 0.1 HRC; 0.1 HRE; 0.1 HRH; 0.1 HR15N; 0.1 HR15T; 1 HB; 1 HV; 0.1 HS; 1 MPa (N/mm2) |
Measuring Accuracy | ± 0.8 µm (~ ± 1.0 HRC) over entire range |
Maximum Test Hardness | 70 HRC |
Test Direction | Any direction (no correction required) |
Test Loads | Preload 10 N / total load 50 N |
Diamond Indenter | Angle (100.0±0.5)°, diameter of flat area of (60±0.5)µm |
Metal Hardness Tester Equotip 3 Indicating Device: | |
Dimensions | 170 x 200 x 45 mm (6.7 x 7.9 x 1.8 inches) |
Weight | 780 g (27.5 ounces) plus battery pack 120 g (4.2 ounces) |
Display | Large QVGA LCD with adjustable contrast and backlight |
Internal Data Storage | 100,000 - 1,000,000 values (depending on data type) |
Interface | Ethernet, USB 1.1, RS 232 |
Battery Type | Rechargeable Li ion or 3 standard size "C" cells |
Battery Max. Charge Voltage | 4.2 V |
Battery Operation Period | Typically 10 hours |
Operating Temperature | 0 to + 50 °C (32 to 122 °F) |
Humidity | Non-condensing, 90% max |