1 Product savings and reduced running costs
2 Minimum aadowntimeaa and cleaning time
3 Reduced conversion times, compared
Port: XIAN
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 1000 Piece/Pieces per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: standard exported package ,or according to the customer's requested.
Delivery Detail: 2~3 weeks
Electromagnetic Flowmeter FES7000 (Fill-MAG)
FES7000-DS21 | |
---|---|
Applications | Hygienic design for food and pharmaceutical industries |
Meter Sizes | DN 1 ... DN 100 1/25 ... 4 in. |
Accuracy | 1 % of rate (Reproducibility 0.2 % of rate) |
Liner | PEEK, Torlon, PFA (vacuum stable) (max. liquid temperature 130 °C / 266 °F) |
CIP / SIP | Water / steam max. 150 °C (302 °F) / 1h |
Signals | End contact / anticipatory contact (fine batching) Selection of active batch quantity Pulse output: passive unscaled (100 % Flow = 10 KHz) Configurable contact output / input (Start / Stop) |
Communication | RS 485 (ASCII) |
Power Supply | 115 / 230 V AC, 24 V AC |
Certificates | 3-A approval, FDA approval, EHEDG |
Description | Converter with 4 different selectable batch quanties (selectable by software or contact). One or two stage batching. The basic flowmeter primary body can be adapted to the existing connection types using threaded adapters such as: Weld stubs Pipe couplings according to DIN 11851 Tri-Clamp according to DIN 32676 Male threaded adapters. Also available in wafer and flanged designs according to DIN, ANSI or JIS standards. |