1.International initiative
2.Patented technology
3.High sensitivity
Port: SHANGHAI
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 10 Set/Sets per Month
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Carton
Delivery Detail: 30DAY
Instrument Introduction
ECL detection is rapidly developing in recent years, capillary electrophoresis analysis of a new detection method.It capillary separation technology and the combination of electrochemiluminescence detection. It can be in the clinical analysis and medicine, virus, immune and other scientific experiments greatly simplify the analysis of the technical difficulty and improve the accuracy of analytical results.
MPI-A capillary electrophoresis with electrochemiluminescence detector system by capillary electrophoresis and electrochemical luminescence detection in one of the more testing interface, and more analysis parameters, multi-control unit system integration equipment.
MPI-A capillary electrophoresis with electrochemical luminescence detector is a combination of capillary electrophoresis and electrochemical luminescence detection in one instrument, but also more than a test interface, multi-parameter analysis, multi-control unit system integration equipment.
It can achieve the same time the sample line separation by capillary electrophoresis, real-time detection of electrochemiluminescence and chemiluminescence signals synchronized display, the electrochemical potential sweep signal, electrochemical electrode current signal and current signal by capillary electrophoresis and its detailed analysis.
Technical parameters
1.MPI-A capillary electrophoresis with electrochemical luminescence detector -
multifunction chemiluminescence detector
Dynamic range: more than 5 orders of magnitude
Measurement accuracy better than 0.05%
2.MPI-A / B-type chemiluminescence detector function:
Wavelength range :300-650nm
Sensitivity: SP> 1000A/Lm
3.MPI-A capillary electrophoresis with electrochemical luminescence detector - electrochemical analyzer:
Potential range:-10V-10V
* Current Range: ± 250 mA
* Reference electrode input impedance: 10E12Ω
* Sensitivity: 1x10E-12-0.1A range
* of 16 input bias current: <50pA
* potential incremental: 1mV
* scan rate :0.0001-200V / S
* Test method: Cyclic voltammetry (CV), linear sweep voltammetry (LSV), chronoamperometry (CA) time-power law (CC), controlled potential electrolysis coulometry (BE ), open circuit voltage - time curve (OCPT)
4.MPI-A capillary electrophoresis with electrochemical luminescence detector - capillary electrophoresis high voltage power supply
Output voltage :0-20KV
Output Current :0-300uA
Main purposes
1. For drugs, amino acids, peptides, proteins and nucleic acid detection of
2. For protein and drug, nucleic acid interaction.