1. Directly display temperature on the spot
2. Automatically break power and alarm
3.High reliability and long life expectancy
Port: XINGANG port
Minimum Order Quantity: 10 Piece/Pieces
Supply Ability: 100 Piece/Pieces per Day
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Carton
Delivery Detail: within two weeks. and will according to your inquiry
Application
It is used on production spot with demand of automatic control and alarming on temperature to directly measure
temperature of liquid, vapor and gas ranging from -80 to +500.
Features
1. Directly display temperature on the spot
2. Automatically break power and alarm
3. High reliability and long life expectancy
4. Many structure forms to meet different demands
Operation Theory
Temperature change results in break or contact of electric contact which leads to operation of relay to realize
automatic control and alarming.
Main Technical Parameters
Executive Standard
JB/T8803-1998
GB3836-83
Nominal Diameter of Dial: 100
Accuracy Class: (1.0), 1.5
Thermal Response Time: ≤40s
Protection Class: IP55
Electric Parameters
Rated Power VA | Max, Working Voltage V | Max, Allowed Current |
10 | 220 A.C | 0.7 A |
24 D.C |
Insulation Resistance
Rated Voltage V | Testing Voltage (D.C) V | Insulation Resistance Ω |
24 D.C | 100 | 7 |
220 A.C | 500 | 20 |
Normal Ambient Condition:
Temperature: -25¬+55°C; Relative Humidity: ≤85%
Setting Point Error:It shall be no more than 1.5 times of basic error limit.
Switch Error:It shall be no more than 1.5 times of basic error limit.