EconDigital Multimeter With Non-contact Voltage Detection Function-YH1003
1)Display: LCD 2000 counts
2)Maximum voltage :600
Port: Shenzhen
Minimum Order Quantity: 10 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month More can be provided according to customers' need
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: carton box for outer,gift box for unit
Delivery Detail: 5-7 days
Digital Multimeter With Non-contact Voltage Detection Function-YH1003
Display: LCD 2000 counts
Maximum voltage :600V
Measuring method: Dual-slope integration A/D converter
3 1/2 digit,(2000 count)LCD.
Back light
When this button is pushed, the Back light of display is on. After about 10 seconds, the Back light is self-off.
The Back light is on again, just push this button once.
Hold button
When this button is pushed, the display will keep the
last reading and “”symbol will appear on the LCD
until pushing it again.
Rotary switch
This switch is used to select functions and desired
ranges as well as to turn on/off the meter.
“COM” jack
Plug in connector for black (negative) test lead.
“10A” jack
Plug in connector for red test lead for10A measurement.
“VWmA” jack
Plug in connector for red (positive) test lead for voltage, resistance and current (except 10A) measurements.
Non-contact voltage detection indicator(red LED) Display
FEATURES
1. Designed to international safety standard IEC 1010-1 CAT III 600V, CAT II 1000V
2. Data hold
3. Auto power off
4. Display: 3 1/2 digit,(2000 count)LCD.
5. DC voltage: 200mV/2V/20V/200V ±(0.5%+3), 600V±(0.8%+5)
6. AC voltage: 200V/600V ±(1.2%+5)
7. DC current: 200µA/2mA/20mA/200mA±(1.0%+3), 10A±(3.0%+5 )
8. Resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ 20M Ω ±(0./%+4)
9. Temperature range: -20°C~1000°C ±(3%+3)
10. Continuity Test
11. Diode test
12. Power: 9V battery, NEDA 1604 or 6F22
13. Size:140mm×67mm×30mm
14. Weight: approx. 112g (including battery)
15. Fuse protection: F 250mA/250V 10A/250V
Comparison between YH1002 & YH1003
Model | YH 1002 | YH1003 |
Measurement Function | ||
DCV | 200Mv/ 2v/ 20v200v± (0.5% of rdg +3 digits)/ 600V | 200Mv/ 2v/ 20v200v± (0.5% of rdg +3 digits)/ 600V± (0.8% of rdg +5 digits) |
AVC | 220V / 600V ± (1.2% of rdg +5 digits) | 220V / 600V ± (1.2% of rdg +5 digits) |
DCA | 200mA/2mA/20mA/200mA± (1.2% of rdg +3 digits)10A± (3% of rdg +5 digits) | 200mA/2mA/20mA/200mA± (1.2% of rdg +3 digits)10A± (3% of rdg +5 digits) |
Resistance | 200W/2K/20KW/200KW/2MW± (0.8% of rdg +4 digits) | 200W/2K/20KW/200KW/2MW± (0.8% of rdg +4 digits) |
Temperature | -20° C to 1000° C. ± (3% of rdg +3 digits) | |
AUDIBLE CONTINUITY TEST / DIODE TEST |