Current/Leakage Monitoring Recorder
1.Function:Testing Leakage current, on-line monitoring, line maintenance
2.Range:0mA~20A
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month
Payment Terms: L/C,T/T,Western Union,Paypal
Contact Supplier
ETCR8000B Current/Leakage Monitoring Recorder
Our buyers have stayed with us for 12 years
12 years of specialized meters
ISO Patent and CE certificate
OEM services available
More information, please kindly view our web site: http://www.etcr.cc/en/
Online store: http://www.aliexpress.com/store/502192
Product Characteristics:
Model: ETCR8000B
1.Function: Testing Leakage current, on-line monitoring, line maintenance
2.Measuring scope:0mA~20A 3.Accuracy:0.01mA
4.Data Storage: 4200 set
Technical Specification
Functions | Measuring AC leakage current and AC current, monitoring current in real-time manner, locating insulation faults and repairing electrical lines. |
Power source | DC6V, alkaline battery LR6 1.5V×4 |
Testing Method | Splitcore type CT, true RMS |
Range | 0.00mA-20A |
Resolution | 0.01mA |
Accuracy | ±2%±5dgt |
Clamp size | 25mm×30mm |
Instrument Dimension | Tester(L×W×H): 75mm ×170mm ×30mm Current clamp(L×W×H): 170mm ×70mm ×38mm |
Mass | Tester: 240g (battery included) Current clamp: 170g |
LCD Dimension | Display field: 44mm×27mm |
Shield Type | Type B: Double shielding |
Sampling Rate | 2 samples/s |
Data storage | 4200 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 10 days at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | A “ OL ” symbol is displayed when a measured value is beyond the measurement range |
Battery . Voltage | A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | 2 m |
Temperature and Humidity | Working: -10ºC~40ºC;below 80%rh |
Storage: -10ºC~60ºC;below 70%rh | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT III(600V), IEC61326(EMC standard) |
Accessories | Tester: 1 PCS, Current clamp: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS |