Home  >  Electrical Instruments  >  Voltage Meters

ETCR4000 Double clamp digital phase meter - ETCR4000

Double clamp digital phase meter, 1. Function:measuring voltage,current and phase, 2. Range:0~360,0~20A,0~500V - more info check here: http://www.buymeasuringtools.com/ETCR4000-Double-clamp-digital-phase-meter-10307378/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: ETCR Model Number: ETCR4000 Display Type: Digital Only Measuring Range: phase:0~360;current:0~200mA/2A... Accuracy Class: Phase: 3,Current:1% 2dgt,Voltag... Operating Temperature: -10~40;85%rh below Dimensions: 92*192*50mm LCD: 3-1/2 LCD display Power supply: DC9V alkaline dry battery LR6*6 ... Sampling speed: About 3 times /s Phase Meter: Double clamp digital phase meter

Product Features:

Double clamp digital phase meter

1. Function:measuring voltage,current and phase

2. Range:0~360,0~20A,0~500V

Business Terms:

Port: Guangzhou

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 1000 Unit/Units per Week

Payment Terms: L/C,T/T

Contact Supplier
ETCR4000 Double clamp digital phase meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: MOQ:1pcs;6 pcs/box;MOQ-OEM:30pcs

Delivery Detail: 3 days after receiving payment

Specifications and Product Details:

ETCR 4000 Double clamp digital phase meter

Product Characteristics:

Measure AC Current and Voltage, Measure the phase between two voltages, two currents, one voltage and one current. Indirectly measure the circuit power and power factor, Judge phase sequence. Clamp Dimension : φ7.5mm×13mm, AC Voltage Range: 0~20V/200V/500V, AC Current Range: 0~200mA/2A/20A, Phase Range: 0~360, resolution: 0.1mA /0.01V/1°.

Product Characteristics

Measure AC Current and Voltage, Measure the phase between two voltages, two currents, one voltage and one current. Indirectly measure the circuit power and power factor, Judge phase sequence. Clamp Dimension : φ7.5mm×13mm, AC Voltage Range: 0~20V/200V/500V, AC Current Range: 0~200mA/2A/20A, Phase Range: 0~360, resolution: 0.1mA /0.01V/1°.

. Technical Specifications

1. Baseline Conditions and Working Conditions

Influence FactorBaseline ConditionWorking ConditionRemarks
Ambient Temperature23°C±1°C-10°C~40°C
Ambient Humidity40%~60%<85%
WaveformSineSineβ=0.05
Signal Frequency50HZ±1Hz45HZ~65Hz
Meter Power Supply9V±0.1V9V±1V
External Electric and Magnetic fieldShould avoid
Tested Wire LocationThe tested wire should be located in the clamp approximate geometric center

2. General Specification

FunctionPhase, AC current, AC voltage, AC leakage current, Direct phase sequence test; Transformer group, Inductive and Capacitive Circuit judgment; Power factor, Power indirect test
Power SupplyDC9V Alkaline batteries (1.5V AA×6)
Power ConsumptionMaximum 35mA when backlight is on, Battery continuously working for 40 hours
5mA when backlight is off, Battery continuously works for 300 hours
Display ModeLCD display, Blue backlight
LCD Size70mm×62mm
LCD Display Domain64mm×54mm
Meter SizeL×W×T: 196mm×92mm×54mm
Clamp Dimensionφ7.5mm×13mm
Sample Rate3 Times/Second
RangeAC voltage: 0~20V/200V/500V
AC current: 0~200mA/2A/10A
Phase: 0~360
The Tested Signal Amplitude Scope in Phase MeasurementPhase U1-U2: 30V~500V
Phase I1-I2: 10mA~10.00A
Phase U1-I2 or I1-U2: 10V~500V, 10mA~10.00A
Reading HoldPress key HOLDto hold the reading, and “DH”displays on the screen
Auto Power off15 minutes after boot
BatteryVoltage DetectionWhen battery voltage is lower than 7.8V, Low batter symbol will display on the screen to remain battery replacement
Weight of MeterHost: 550g (with batteries), Clamp: 170g×2 PCS, Voltage Test line 250g
Length of Test Line1.5m
Length of Current Clamp Lead2m
Working Temperature and Humidity
-10°C~40°C; below 80%Rh
Storage Temperature and Humidity-10°C~60°C; below70%Rh
Input ImpedanceU1 or U2 Voltage testing: 2MΩ
U1U2 phase testing is: 40 KΩ
Voltage-ResistanceOne minute tolerant duration between meter PCB and shell with 1000V/50Hzsine wave AC voltage input. One minute tolerant duration when input 500V/50Hz sine wave AC voltage between the U1 and U2 input electrodes
InsulationBetween meter inner PCB and shell: ≥10MΩ, Between both voltage Inputs: ≥10MΩ
StructureDual Insulation

3. Basic error and performance indicators under baseline conditions

ItemsRangeResolutionTolerance
Voltage20V0.01V±(1.2%rdg+2dgt)
200V0.1V
500V1V
Current200mA0.1mA±(1.0%rdg+2dgt)
2A1mA
10A10mA
Phase0~360°±3°

. Configuration List

Meter1 Piece
Meter box1 Piece
Current clamp2 Pieces
Test line4 Pieces (2 pieces in Red and 2 pieces in Black)
Battery1.5V AA, 6 Pieces (alkaline battery: 1.5V AA)

. Field Application

ETCR4000 Double clamp digital phase meter suppliers    ETCR4000 Double clamp digital phase meter manufacturers