Duct PT100 temperature sensor - TS-N10-D-20

NTC 20K, NTC 10K, PT100 temperature sensor, Temperature measurement for air ducts., Wide range of temperature probes - more info check here: http://www.buymeasuringtools.com/Duct-PT100-temperature-sensor-10334057/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: CH-BA Model Number: TS-N10-D-20 Usage: Outdoor Theory: Temperature Controller probe: 10cm, 15cm, 20cm: NTC 20K, NTC 10K, PT10...

Product Features:

NTC 20K, NTC 10K, PT100 temperature sensor

Temperature measurement for air ducts.

Wide range of temperature probes

Business Terms:

Port: Shanghai

Minimum Order Quantity: 50 Piece/Pieces

Supply Ability: 500 Piece/Pieces per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Duct PT100 temperature sensor
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Features

· Thermistor,PT or NI sensing elements to fit your system

· Simple and secure installation

· Wide range of temperature probes

· Compact size and modern design

Applications

· On return air ducts to measure heating/cooling return air

· On supply air ducts to measure heating/cooling supply air

· In heat exchangers and air handling units to control heating/cooling coils for temperature and humidity control

· As frost protection sensor

Temperature Sensor

The sensor measures the temperature by use of a NTC, PT or NI sensing element. The sensing element is either a glass packed thermistor with a negative temperature coefficient or a platinum film sensor or a thin nickel layer on a ceramic substrate. Its resistance changes according to the temperature. The change follows a specified curve. Below is a list of available sensor elements, curves and accuracies:

Item nameSensing elementCurveCompatible with
N18Thermistor 1.8k at 25 °CCurve 5TAC, CSI
N3Thermistor 3k at 25 °CCurve 6Alerton
N10Thermistor 10k at 25 °CCurve 24Hysine, Alerton,ALC, Delta,Trane, CSI
N11Thermistor 10k at 25 °CCurve 7Andover, Invensys, Carrier, KMC
N20Thermistor 20k at 25 °CCurve 20Honeywell
N100Thermistor 100k at 25 °CCurve 9Siemens SBT
Tp1PT1000.3851ohm/KHoneywell
Tp2PT10003.851ohm/KJohnson Control
TK5NI10005000ppm/kSiemens SBT
Ordering

Ordering number:TS-XX-D-YY

XX indicates the sensor element optional,see table above.

YY indicates the probe length. Standard probe length is 20 cm.

For example:TS-N10-D-20

-N10 indicates the sensor element is Thermistor 10k .

-20 indicates the probe length is 20 cm.

Duct probes should be installed directly on the duct, in an area where the air stream is well mixed:

· Locate a supply air sensor two or three meters down stream from the nearest fan and coil.

· Mount the return air sensor close to the air inlet but downstream from a return fan if one is present.

· To install the sensor, assemble base plate and probe, then drill a 8 mm hole and two 3 mm holes on a diameter of 25 mm in the duct.

· Use two self-tapping sheet metal screws to tighten the mounting circuit in the cover.

· Connect the wires according to the wiring diagram to the measuring circuit in the cover:

o The Thermistors require two conductors; normally 18ga unshielded twisted pair.

o The PT100, PT1000 and NI1000 sensors come with each two terminal connectors in order to connect up to four conductors for compensating conductor resistance.

· Assemble the cover with the mounting plate.

· Insert the assembled probe through the center opening of the mounting plate into the air stream.

· Tighten the horizontal screw on the mounting plate to fix the probe to the duct.


Technical Specification

Sensing Probe

Thermistor:

Range

Accuracy

NTC

-30----70°C

±0.5k

Platinum-Film:

Range

Accuracy

PT, 0.3851ohm/k

-30----70°C

±0.3k

Nickel Thin Layer

Range

Accuracy

NI, 5000 ppm/k

-30----70°C

±1k

ConnectionConnection Terminals2.5 mm2

Environment

Operation
Climatic Conditions
Temperature
Humidity
To IEC 721-3-3
class 3 K5
-4070°C
<95% r.h.
Transport & Storage
Climatic Conditions
Temperature
Humidity
Mechanical Conditions
To IEC 721-3-2 and IEC 721-3-1
class 3 K3 and class 1 K3
-4080°C
<95% r.h.
class 2M2

Standards

conform according to
EMC Standard 89/336/EEC
EMEI Standard 73/23/EEC

EN 61 000-6-1/ EN 61 000-6-3
Automatic electrical controls for household and similar use

Special requirement on temperature dependent controls

EN 60 730 1

EN 60 730 2 - 9

Pollution ClassNormal acc. To EN 60 730,RoHS compliant
Degree of ProtectionIP56 to EN 60 529
Safety ClassIII (IEC 60536)
Housing MaterialsCover & Mounting Plate
Probe
Fire proof ABS plastic

Stainless Steel

General

Dimensions [mm]Cover: 42 x 112 x 88 (H x W x D)
Probe: ø 6 x 200 (Diameter x L)
Weight (including package)135g