Dual channel vibration analyzer
vibration analyzer and balancer
portable vibration analyzer
spectrum analyzer
Balancer
Port: Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 200 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: carrying case with sponge insert
Delivery Detail: 10 days after you confirmed the order
Features
l 3.5 inches TFT large LCD screen, simple flow chart, compact and light weight, more convenient operation.
l 1GB large storage capacity, can meet high-capacity data collection requirement.
l Wide analysis frequency (0~40KHz), high spectrum resolution ratio, can meet the requirement for precise and complex equipment (high-speed gear) analysis.
l Very flexible parameters configuration including high and low band pass filter, sampling length and sampling frequency etc. Can meet the requirement of data acquisition for various equipments.
l Route or off route data acquisition are allowable, off route data acquired can be saved by sequence number or by measuring point number.
l Comprehensive functions:
Main technical parameters
Items | Specification |
Analog input | |
Channels | Channel 1:vibration(ICP accelerometer),Voltage(±21V AC or DC) Channel 2:vibration(ICP accelerometer),Voltage(±21V AC or DC),tacho channel |
Transducer | Accelerometer, Velocity, Displacement, voltage transducer |
Signal range | ±21V |
A/D conversion | 24 bit |
Analog measurement | |
Integration | once,twice integration |
Maximal analysis frequency | 40kHz(dual channel Maximal: 20kHz) |
Sampling frequency | 256Hz – 102.4kHz |
Dynamic signal range | 96dB |
Precision | 1%( 0.1dB) |
Signal processing | |
Configuration | Sampling frequency, low band pass filter, Sampling length,users can set any value as needed. |
Lines | 400, 800, 1600, 3200, 6400, 12800 |
Time domain Sampling | 1024, 2048, 4096, 8192, 16384, 32768 |
Window function type | Hanning, Rectangle window |
Averaging | Linearity, peak hold |
Averages | 1,2,4,8,16,32,64,128 |
Analysis | |
Long time domain waveform | Maximal waveform is 10M, maximal analysis frequency of Dual-channel is 10KHz, maximal analysis frequency of single channel is 20K. |
Overall value | Minimum interval: 0.1 sec |
XPM measurement | view XPM and phase difference spectrum simultaneously |
Dynamic balance | On site 1 or 2 plane dynamic balance by Influence coefficient method |
Coast up/down testing | Equal time intervals, Equal RPM intervals |
Basic index | |
LCD | True color LCD, 320×240pixles, contrast adjustable |
Keys | 22 keys |
Communication | USB, 900KB/s |
Storage capacity | 1G |
iButton | DS1990A |
Communication | USB 2.0 |
Battery | Rechargeable Li-ion battery, charging time around 4 hours; working Time (Continuous) >10 Hours; two channel working time >8 Hours |
Temperature | (-10~50)°C |
Humidity | 95% RH without condensate |
Protection grade | IP65 |
Dimension | 190 X110 X50mm |
Weight | 660g |