Dual Diplay Digital Process Calibrator.
Digital Process Tester.
Dual Display.
Measuring and Output Source.
High-Accuracy
Port: Shenzhen
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 120000 Piece/Pieces per Month
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Carton box for outer, gift box for unit
Delivery Detail: 5~30 days
Dual Display Digital Process Calibrator. process tester.
• measure and output signal simultaneously.
•3,3/4 dual display
• Precision 1000V, 400 mA digital multimeter
• Measure AC and DC volts, AC and DC current, resistance, continuity, frequency and temperature and break-and-make, diode and triode test.
• 0.1% DC voltage accuracy
• 0.1% DC current accuracy
• True rms AC voltage measurement to 400Hz
• Frequency measurement to 200kHz
• Diode test and continuity beeper
• 0 mA current source/simulator
• Simultaneous mA
• Power: Built-in rechargable battery
• Operate Temperature: -10°C ~ 40°C
• Storage Temperature: -20°C ~ 55°C
• Size: 195×92×55mm
• Weight: 600g
Technical Specification:
1. Measure Function Description:
Measure Function | Range | Resolution | Accuracy |
DC voltage | 400mV | 0.1mV | ± (0.1% reading + 3) |
4V | 1mV | ||
40V | 10mV | ||
400V | 100mV | ||
1000V | 1V | ||
AC voltage | 4V | 1mV | ± (0.8% reading + 3) |
40V | 10mV | ||
400V | 100mV | ||
700V | 1V | ± (1.0% reading + 10) | |
AC current | 400mA | 0.1mA | ± (1% reading + 5) |
4000m A | 1mA | ||
40mA | 10mA | ||
400mA | 100mA | ||
DC current | 400mA | 0.1mA | ± (0.1% reading + 5) |
4000mA | 1mA | ||
40mA | 10mA | ||
400mA | 100mA | ||
Resistance | 400Ω | 0.1Ω | ± (0.3% reading + 5) |
4kΩ | 1Ω | ||
40kΩ | 10Ω | ||
400kΩ | 100Ω | ||
4MΩ | 1kΩ | ||
40MΩ | 10kΩ | ± (2.0% reading + 5) | |
Capacitance | 40nF | 10pF | ± (2.0% reading + 10) |
400nF | 0.1nF | ||
4mF | 1nF | ||
40mF | 10nF | ||
100mF | 100nF | ||
Frequency | 9.999Hz | 0.001Hz | ±10 |
99.99Hz | 0.01Hz | ||
999.9Hz | 0.1Hz | ||
9.999kHz | 1Hz | ||
99.99kHz | 10Hz | ||
199.9kHz | 100Hz | ||
>200kHz | Only for reference |
2. Output Function Description:
Output Function | Range | Resolution | Accuracy |
DC Voltage signal | 10V | 10mV | ± (0.1%reading+5) |
100mV | 100μV | ||
DC Current signal | 22mA | 10μA | ±(0.1%reading+5) |
Frequencysignal | 1~100Hz | 0.01Hz | ±0.1Hz |
100Hz~1kHz | 0.1Hz | ±0.5 Hz | |
1~10kHz | 1Hz | ±5 Hz |
3. Power Supply Output:
Voltage | Accuracy | Load capacity |
24V | 2% | 30mA |
OR:
Factory Tour:
Accessories:
Test leads, Thermoelectric Couple, Multi-purpose socket, Test Clip, 24V output wire, Charger, Instruction.