Digital water flow meter
Minimum Order Quantity: 1 Piece/Pieces
Payment Terms: L/C,D/P,T/T
Contact SupplierPackaging Detail: wooden case
Delivery Detail: 3-7days
Digital water flow meter
Main Technical Parameter:
Suitable tube caliber: DN25~DN2600(below DN25 unstandard)
Electrode material: 316L(stainless steel), HC, HB, Ti, Ta
Suitable Medium: Liquid with conductive ratio more than 5 μs/cm
Measuring range: 0.1~10m/s (extendable to 15m/s)
Upper limit of span: 0.5~10m/s. 1~5m/s recommended
Accuracy class: 0.3, 0.5, 1.0
Output signal: 4~20mADC, load≤ 750Ω, 0~3kHz, 5V with source and changeable width. High terminal and effective frequency output, RS485 interface
Operation pressure: 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)
Fluid temperature: 20C~80C, 80C~130C, 130C~180C according to liner material
Environmental temperature: sensor40~80º C. Transducer 15~50º C
Environmental humidity: ≤85%RH (at 20º C)
Cable outlet size: M20x1.5
Power supply: 220VAC± 10%, 50Hz± 1Hz, 24VDC± 10%
Power consumption: ≤8W
Protection ratings Combined type: IP65. Separate type: Sensor IP68, transducer IP65
Materials of liner: PTFE, soft rubber etc
Connection of flange: GB911988(DIN2051, BS4504)
Earthing material: 1Cr18Ni9Ti (stainless steel), HC, Ti, Ta, Cu
Flow Rate Range:
Diameter(mm) | Flow Rate Measurement (m3/h) | Diameter(mm) | Flow Rate Measurement (m3/h) |
φ15 | 0.06~6.36 | φ450 | 57.23~5722.65 |
φ20 | 0.11~11.3 | φ500 | 70.65~7065.00 |
φ25 | 0.18~17.66 | φ600 | 101.74~10173.6 |
φ40 | 0.45~45.22 | φ700 | 138.47~13847.4 |
φ50 | 0.71~70.65 | φ800 | 180.86~18086.4 |
φ65 | 1.19~119.4 | φ900 | 228.91~22890.6 |
φ80 | 1.81~180.86 | φ1000 | 406.94~40694.4 |
φ100 | 2.83~282.60 | φ1200 | 553.90~55389.6 |
φ150 | 6.36~635.85 | φ1600 | 723.46~72345.6 |
φ200 | 11.3~1130.4 | φ1800 | 915.62~91562.4 |
φ250 | 17.66~176.25. | φ2000 | 1130.4~113040.00 |
φ300 | 25.43~2543.40 | φ2200 | 1367.78~136778.4 |
φ350 | 34.62~3461.85 | φ2400 | 1627.78~162777.6 |
φ400 | 45.22~4521.6 | φ2600 | 1910.38~191037.6 |