Digital temperature humidity monitor
2-16 channels of input signals
Accuracy:0.1degree
1~4 alarm
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Year
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: Carton packaging or according to request
Delivery Detail: 10days
Digital Temperature Humidity Monitor
CTM series multichannel temperature controller that measure and display 2-16 channels of input signals one by one is displayed by way of. automatic switched channel.It may support many kinds of input signals(such as temperature sensor,humidity sensor ,pressure sensor,liquid level sensor,flow sensor and so on ) using at the same time and also can be used with micro-printer to print both data and curve. It has the function of RS485 communication mode to exchange datas with PC or PLC .we choose high .quality components for the merer as well .All these endow the meter high performance in control.
1.Technical standard
Supply voltage | 220VAC,50/60Hz or DC24V | working circumstance | temperature:-10-5degree humidity:<85% |
measurement accuracy | ±0.5%F.S | consumed power | 4w |
display accuracy: | 0.1degree | setting method | digital setting using front panel keys |
sampling rate | 150ms per channel | number of channels | 2 to 16 channels selectable |
2.Product model(Please order by filling the blanks :)
CTM-1 X 2 3-4 5-6-7 8-9 10-11-12
SN | Name | Explanation |
1 | Panel dimension (mm) | 1 160*80*85 9 96*96*100 |
2 | Control methods | 08 TO 16 8 to 16 channels temperature controller seclectable |
3 | First Input methods | Thermocouple or RTD or voltage or current |
4 | starting channels of first input signal | 01 channel |
5 | ending channels of first input signal | 02-16 channel (choose any one channel you need) |
6 | second input signal | Thermocouple or RTD or voltage or current (be neglected when only one kind of input signal) |
7 | starting channels of second input signal | 01 channel (be neglected when only one kind of input signal) |
8 | ending channels of second input signal | 02-16 channel (be neglected when only one kind of input signal) |
alarm output | MM 2 groups relay ourput TL extending relay output NN none | |
transmitting output | 5 0-20mA current output 7 0-10mA current output 8 4-20mA current output N none (can be neglected) | |
communication | C with RS485 communication module interface N none (can be neglected) | |
.printing | Z with micro-printer output signal N none (can be neglected) | |
9 | supply voltage | A DC48V B DC24V E AC110V N AC220V |
Mini-printer: