Digital gauss meter HGS-20C
Tesla meter
magnetic measurement
fast delivery
competitive price
Port: Beijing
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 200 Unit/Units per Month
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: carrying case
Delivery Detail: within 5days
Digital gauss meter HGS-20C
The Tasla meter is a special instrument used for inspecting & checking flux density ,which is also one of the most universally devices in the field of magnetic measurement.
Model HGS-20C digital Tasla meter is controlled by the SCM, which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’s person. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value, As mT or Gs unit of display can be change over, Measuring range of 200mT or 2000mT can be chose, and others that as resetting zero by key and so on.
Reality Working Domain:
1) Magnetic field distribution of material surface
2) Working in the magnetic field produced from some instruments such as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
3) Leakage Magnetic iron-surface
The connecting cable of the probe shall not be kneaded or pulled forcibly, the probe bracket shall not be beaten or impacted and the probe lead wire and welding spot shall not be contacted with other conductor or in short circuit.
a) Illustration of measuring field (see top fig.)
As holding the sensor,(no staff guage side)touch the surface of measuring object lightly.
b) The wrong method of holding the sensor:
No making the top of sensor to touch the surface of measuring object forcibly.(As the right Fig) So that it’ll damage the sensor easily.
Main Technical Parameters
Rang: 0~200mT~2000mT
Accuracy: ±5%
Sensitivity: 0.01mT, 0.1mT
AC Magnet Field: 50-200Hz
Temperature of environment: 5°C-40°C
Relative humidity: 20%-80%(no condensation)
Power Supply: Battery 9V, constant DC power
Dimension: 230mm×205mm×80mm
Weight: N.W: 1Kg G.W:1.2Kg
Display: 4½ LCD
Shape of the device:
Screen of Display
Manipulation Procedure
Press the key RANGE switchover again and again , the measurement range would be transformed within 0-200 mT or 0-2000 mT.
Press the key DC/AC switchover again and again , the DC/AC mode would be selected.
Press the key(5) of conversion , the display unit would be transformed from mT to Gs.
Keep the sensor far away from magnetic field what it is not in the state of holding .If the display screen should not show “000”.you must press the key(7) to adjust it to zero.
Note: After change over the measurement range or transform the AC/DC mode , you all need to reset zero.
Press the key(6) to change over normal measurement or Peak-value holding .
10. Reset Peak-value holding
When keeping the Peak-value holding , you need to measure new peak value and the forecast value will be lower forecast. Thus you could press the Reset button(7) to make it show a new peak value.
11. If the measurement is finished, the cap should be screwed up. It may be better to remove the battery from the case to prolong its time of use.
12. The Hall probe can be replacable .The difference from original probe to others is 2%.
Note: 0.1mT=1Gs 1T=10000Gs
Maintenance and Notes
If you don’t find an damage in it , please send it to our company . It’s maybe wrong within the circuits.
If don’t ensure that the instrument is operated correctly as described below, there would be error or
mistake.
1,Don’t attempt to repair, or disassemble, and any reconstruct this instrument.
2, Use only recommended power accessories.
3, Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
4, Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
5, Do not allow hands or other objects with dirt to touch the probe.
6, Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, as well as humidity, water, oil, rust air, vibration and others.
7, It would be used and stored up in temperature range
8, You should not move the instrument rapidly between high and low temperature to avoid condensation.
9, Never place the instrument in the places close to the machine generating strong magnetic field, such as magnet-charger, demagnetize coil, microwave oven, electric welding equipment electric motor and etc.
10,In conclusion, we suggest you calibrate the instrument in time.
Whole Set of the Instrument:
1.Model HGS-20C Digital Tasla meter 1 pcs.
2.Instruction for use 1pcs
3.Produce Certificate 1pcs
4.Probe 1pcs