Stroboscope Xenon tube, + Laser photo Tachometer, ACV power STROBOSCOPE
Port: TAIWAN
Contact Supplier
Xenon tube, + Laser photo Tachometer, ACV power STROBOSCOPE
Model : DT-2289 ISO-9001, CE, IEC1010
Features :
* Stroboscope use high intensity XENON tube.
* LCD display with back light.
* Stroboscope range : 100 to 10,000 RPM.
* External trigger for stroboscope.
* Photo tachometer range : 10 to 99,999 RPM.
* Photo tachometer use the laser light beam.
* DCV power supply via external AC/DC adapter included )
+ Laser Photo Tachometer, Contact Tachometer
COMBINATION STROBOSCOPE
Model : DT-2289
1. FEATURES 2-2 Electrical Specifications of Stroboscope
* Combination Stroboscope with 3 functions : Stroboscope Specification
Digital Stroboscope, Laser Photo Tachometer, Stroboscopic 100 to 15,000 flashes per minute (FPM).
Contact Tachometer ( optional probe ), 3 in 1 , Flash Rate Low range : 100 to 1,000 RPM/FPM.
intelligent function. High range : 1000 to 15,000 RPM/FPM.
* The Digital Stroboscope is used the microprocessor Accuracy ± ( 0.05% + 1 digit ).
circuit design, high accuracy, digital readout, light Resolution 0.1 FPM/RPM (less than 1,000 FPM/RPM)
duty, that is ideal for inspecting and measuring the 1 FPM/RPM ( > 1,000 FPM/RPM ).
speed of moving gears, fans, centrifuges, pumps, External Input signal : 5V to 30 V rms,
motors and other equipment used in general TriggerInput 5 to 15,000 RPM/FPM.
industrial maintenance, production, quality control,
laboratories and as well as for schools and colleges Flash Tube Specification
for demonstrating strobe action. Flash tube Xenon lamp.
* Back light high visible LCD display gives exact reading Flash Duration Approximately 60 to 1,000
with no guessing or error and saves battery energy. microseconds.
* High precision both for Stroboscope and Tachometer Flash color Xenon white 6,500 K degree.
measurement. Flash energy 4 Watts-seconds (joules).
* Xenon flash tube with plug and socket, easy to make Beam Angle 80 degrees.
the tube replacement. Flash tube It is required to change the flash tube
* Use an exclusive one chip MICRO-PROCESSOR replacement when the instrument start to flash
LSI-circuit and crystal time base to offer high accuracy irregularly at speeds of 3600 RPM/FPM
measurement & fast measuring time. or more.
* Wide measuring range. Flash tube with plug and socket, easy to
* Stroboscope build in external trigger input. make the replacement.
* Long distance Laser Photo Tachometer build in. Operating duty For prolong life and safety, please
* Stroboscope use high bright xenon tube. Cycle adhere to the following operation duty
* Optional Contact Tachometer probe is available. cycle: < 2000 RPM - 2 hours
* Compact and heavy duty housing case. 2000 to 3600 RPM - one hour
3601 to 8000 RPM - 30 minutes
> 8000 RPM - 10 minutes.
2-1 General Specifications * 10 min. cooling off period between cycles.
Display 5 digits ( 0 to 99999 ) LCD display.
Circuit Exclusive one-chip design microprocessor 2-3 Electrical Specifications of Laser Photo
LSI circuit. Tachometer
Measurement Stroboscope Range 10 to 99,999 RPM
Unit : FPM ( rotation per minute ). Accuracy ± ( 0.05% + 1 digit ).
build in external trigger input. Sampling Time 1 sec. ( 60 RPM ).
Laser Photo Tachometer Photo 50 - 2,000 mm typically.
Unit : RPM ( rotation per minute ). Tachometer * Spec. of detecting distance are that
Contact Tachometer detecting under the size of reflecting tape is 10
Unit : RPM ( rotation per minute ). distance mm square & the measuring RPM
Surface speed ( ft/min., m/min ) value is 1,800 PPM. The max. & min.
* It should cooperate with optional detecting distance may change under
contact probe ( TA-35 ). different environment, different
Sampling Time Approx. 1 second. reflecting tape or the measuring RPM
Calibration Crystal time base and microprocessor beyond 1800 PRM.
circuit, no external calibration process Resolution 0.1 RPM < 1,000 RPM
required. 1 RPM >=1,000 RPM
Operating 0 to 50 °C ( 32 to 122°F ) Time base Quartz crystal
Temperature Laser light * Less than 1 mW.
Operating Less than 80% R.H. source * Class 2 laser diode. Red. Wave length
Humidity is 645 nm approximately.
Power Supply AC( 100V to 240V ) to DC 9V ( 3A ) source * Class 2 laser diode. Red. Wave length
adapter. is 645 nm approximately.
Power Stroboscope ( 3600 FPM ) :
Consumption DC 2.4 A. 2-4 Electrical Specifications of Contact
Laser photo Tachometer ( 3600 RPM ) : Tachometer ( Optional Probe, TA-35 )
DC 50 mA. Range Contact Tachometer :
Weight 1 Kg ( 2.2 LB ). 0.5 to 19,999 RPM
Dimensions 21 cmx12 cmx12 cm (8.3"x4.8"x4.8"). Surface Speed ( m/min. ) :
Accessories Operation manual...........................1 PC. 0.05 to 1,999.9 m/min.
Included AC( 100V to 240V ) to DC 9V adapter Surface Speed ( ft/min. ) :
.....................................................1 PC. 0.2 to 6,560 ft/min.
Reflective tape............................... 1 PC. Accuracy ± ( 0.05% + 1 digit ).
Optional Contact Tachometer probe Sampling Time 1 sec. ( 6 RPM ).
Accessories ................................ Model : TA-35 Resolution 0.1 RPM < 1,000 RPM
Flash Xenon tube.......Model : TBXE-2289 1 RPM >=1,000 RPM
DC 1.2 V Ni-MH recharge batteries, 0.01 m/min. >= 100 m/min.
UM-1/D size ( Model : BAUM-1) x 4 PCs. 0.1 m/min. > 100 m/min.
DC 1.2 V Ni-MH batteries charger 0.1 ft/min. < 1000 ft/min.
with AC adapter, complete set. 1 ft/min. >= 1,000 ft/min.
Model: BACH-110 ( AC 110V power ) Accessories RPM adapter (CONE).................... 1 PC.
Model: BACH-220 ( AC 230V power ) Included RPM adapter (FUNNEL)................. 1 PC.
Surface speed test wheel............... 1 PC.
* Appearance and specifications listed in this brochure are subject to change without notice. A