Home  >  Electronic Measuring Instruments  >  Other Electronic Measuring Instruments

Digital LCR Meter TH2818 - TH2818

1.Digital LCR with transformer test, 2.Frequency: 20Hz-300KHz, 3.DC bias voltage, 4.10-points list sweep, 5.High quality with CE - more info check here: http://www.buymeasuringtools.com/Digital-LCR-Meter-TH2818-10312543/

Quick Brief

Place of Origin: Jiangsu China (Mainland) Brand Name: Tonghui Model Number: TH2818 Frequency: 300KHz Accuracy: 0.01% Output impedance: 30Ω and 100Ω selectable

Product Features:

1.Digital LCR with transformer test

2.Frequency: 20Hz-300KHz

3.DC bias voltage

4.10-points list sweep

5.High quality with CE

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 50 Set/Sets per Month

Payment Terms: T/T

Contact Supplier
Digital LCR Meter TH2818
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

TH2818 is an auto component analyzer with high accuracy, wide measurement range and six-digit resolution. TH2818 can be used for incoming inspection of components, quality control on product line and laboratory use over a wide measurement range up to 300kHz with step of 0.01Hz, signal level from 5 mV to 2V, and DC internal bias voltage. HANDLER, GPIB, RS232C interfaces help build an automatic component measurement system, communicate with the computer and record the test results.

Measurement function

Measurement parameter|Z|, |Y|, C, L, X, B, R, G, D, Q, θ

DCR, Turn-Ratio, Phase

Basic accuracy0.05%
Equivalent circuitSeries, parallel
Mathematical functionΔABS, Δ%
Range modeAuto, Hold, Manual
Trigger modeInternal, Manual, External, BUS
Measurement

Time (≥1kHz)

Fast: 32ms, Medium: 90ms, Slow: 650ms
Average time1—255
Delay time0—60s, with step of 1ms
Calibration functionOpen/short frequency point, full frequency correction, Load correction
Measurement terminal5-terminal
Display modeDirect, Δ, Δ%, V/I (voltage/current monitor)
Display320×240 dot-matrix graphic LCD display with 6-digit resolution

Measurement signal

Signal frequency20 Hz-300 kHz, with resolution of 10mHz
Output impedanceTurns measurement: ≤2V, 10Ω;

>2V, 30Ω

Others: 30Ω , 100Ω selectable

Test levelLCR measurement: 5mV-2V

Turns measurement: 5mV-4V

Automatic level range: 10mV-1V

Resolution: 1mV, accuracy: 5%

DC bias source0V, 1.5V, 2V, accuracy: 1%

0-10V DC bias voltage and 0-100mA DC bias current can be added while using TH1802A

Measurement display range

|Z|, R, X0.00001Ω — 99.9999MΩ
DCR0.001Ω — 99.9999MΩ
|Y|, G, B0.0000µS — 99.9999S
C0.00001pF — 9.9999F
L0.00001µH — 9999.99H
D0.00001 — 9.99999
Q0.00001 — 99999.9
θ (DEG)-179.999º — 179.999 º
θ (RAD)-3.14159 — 3.14159
Turn-Ratio1:0.01—1:100
Δ%-999.999% — 999.999%

Comparator and interface

Comparator10-bin sorting, bin counter
Memory20 sets of instrument settings saved
InterfaceRS232C, USB disk adapter (option),

Handler (option), GPIB (option)

Digital LCR Meter TH2818 suppliers    Digital LCR Meter TH2818 manufacturers