Home  >  Testing Equipment

DZ603-3B Portable Electrical Meter Calibrating Device - DZ603-3B

1.Certificate: ISO 9001, 2.Accuracy class: 0.05, 0.1, 3.Can simultaneously test 3 pcs single-phase & three-phase energy meters. - more info check here: http://www.buymeasuringtools.com/DZ603-3B-Portable-Electrical-Meter-Calibrating-Device-10017203/

Quick Brief

Place of Origin: Henan China (Mainland) Brand Name: SMS Model Number: DZ603-3B Power: Electronic Usage: Meter testing Accuracy class:: 0.05, 0.1; Certificate:: ISO 9001; Meter Positions: 3

Product Features:

1.Certificate: ISO 9001

2.Accuracy class: 0.05, 0.1

3.Can simultaneously test 3 pcs single-phase & three-phase energy meters.

Business Terms:

Port: As per your request

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 10 Set/Sets per Week

Payment Terms: T/T

Contact Supplier
DZ603-3B Portable Electrical Meter Calibrating Device
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Plywood case

Delivery Detail: 20 days

Specifications and Product Details:

DZ603-3B Portable Electrical Meter Calibrator

1)Accuracy classes: 0.1 , 0.05

2)Model: DZ603-3B

3)Equipped with 0.05 class three phase reference standard meter

4)The maximum output current: 120A; Ranges: 0.1A, 0.5A, 1.0A, 2.5A, 5A, 10A, 20A,
50A, 60A(72A max)

5)Voltage is divided into four ranges: 57.7V, 100V, 220V, 380V6)Voltage output power: 280VA per phase, current power: 450VA per phase

7)0.01%.For each range of current and voltage, 0~120% of the range value can be
continually adjusted, the resolution is better than 0.01% of range value
8)Accuracy of Indication Meter: Voltage meter: class 0.5, Current meter: class 0.5,
Frequency meter:class 0.3 phase meter: class0.3
9)Phase scope 0~359.9 degrees, adjusted resolution is 0.1 degree

10)Testing points of power factor: 0.5C, 0.8C, 1.0, 0.8L, 0.5L,

11)Range of frequency is from 45.00 to 65.00Hz, adjusted resolution is 0.01Hz

12)Shall set and measure 2-21 times harmonic and measure the distortion

13)Output power stability: 0.05%(PF=1.100Sec)

14)Wave distortion of outputting: < 1%

15)Working ambient temperature: 23 deg¡À2 deg, relative humidity is less than 85%.
16)Voltage supply: AC3¡Á220V+10% (or as per your request) 50Hz

DZ603-3B Portable Electrical Meter Calibrating Device suppliers    DZ603-3B Portable Electrical Meter Calibrating Device manufacturers