material melting point melting heat, crystallization point , phase change , thermal stability and glass transition temperature.
Port: According to your request
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 10 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Standard export packing or according to your request
Delivery Detail: 45-75days
DSC0901 Differential Thermal Analyzer
This analyzer is designed and produced according to national standard GB17391-1998 and ISO/CD11357/6. It tests the quality change following temperature change under the process temperature control (heating, cooling, constant temperature and cycle). The tester is used to test the quality or weight change of material dehydration, decomposition, evaporation, distillation in a a particular temperature, such as: degradation of metal organic, composition of coal, the thermal stability of polymer, the filtration of catalyst, the performance of explosives, as well as reaction kinetics studies.
Products are mainly for industrial users, research and teaching and are widely used in the new R & D, process optimization and quality control of various materials and chemistries. They mainly measure the heat-related physical and chemical changes, such as material melting point melting heat, crystallization point crystallization heat, phase change response thermal, thermal stability (oxidation induction period) and glass transition temperature.
The main technical parameters:
1. Differential thermal range: ± 2000 uv;
2. DSC range: ± 10, ± 20, ± 50, ± 100, ± 160, ± 200 mW, can automatically switch;
3. Temperature range: common operating temperature: room temperature ~ 450 , room temperature ~ 1150 , ~ 1400 and ~ 1650 to be chosen. Heating rate: 0.1 ~ 30 / min (can be set);
4. The ways of temperature control: heat up, constant temperature, cooling, intelligent control system with PID;
5. Display usage: through the liquid crystal display or PC display;
6. Data processing: use intelligent software to achieve all processing and high-resolution A / D (24 bit bit), in the process of data collection differential thermal baseline can be adjusted automatically through software;
7. Atmosphere control: gas flow meter, gas converter device, nitrogen, oxygen (gas mass flow meter);
8. Gas flow: ≤ 200ml/min, N2, O2;
9. Maximum load: 2g;
10. The smallest sub-degrees value: 2ug;
11. Sensitivity: 10ug ;
12. Thermogravimetric range: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000mg;
13. Thermogravimetric differential coefficient range: 0.1, 0.2, 0.5, 1, 2.5, 10mg/min;
14. Output ways: printer, recorder, etc;
15. Working Power: 220V / 50Hz ± 1Hz.
We are specialized in tester, instrument&furnace of ceramics, inorganic non-metallic materials, glass,cement&engineering test.