Home  >  Analyzers  >  Other Analysis Instruments

DP-02P Laser Particle Size Analyzer - DP-02P

Applications:The measurement of fog drops, Measuring Range:1.0~1500um, Repeatability:< 3%( for standard particles) - more info check here: http://www.buymeasuringtools.com/DP-02P-Laser-Particle-Size-Analyzer-10334148/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: BEATOP Model Number: DP-02P Measuring Range: 1.0-1500μm Repeatability: < 3%( for standard particles) Measurement Duration: 1-2 minutes Number of Detectors: 32 Design: Specially designed for the measurement ... Application: The measurement of fog drops

Product Features:

Applications:The measurement of fog drops

Measuring Range:1.0~1500um

Repeatability:< 3%( for standard particles)

Business Terms:

Port: Zhuhai

Minimum Order Quantity: 1 Set/Sets n/a

Supply Ability: 150 Set/Sets per Month n/a

Payment Terms: L/C,T/T

Contact Supplier
DP-02P Laser Particle Size Analyzer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: seaworthy packing

Delivery Detail: 1 month after order confirmation

Specifications and Product Details:

Laser Particle Size Analyzer

Model:DP-02P

Applications:The measurement of fog drops.

Features:

1.Specially designed for the measurement of sprays, the structure of the instrument can be changed according to requirements.

2.Multiple Fourier lens with different focus are available to change to get different measuring ranges.

Laser Particle Size Analyzers Selection Guide

ModelsApplicationsDispersantMeasuring RangeFeatures
Easysizer20Powders, suspensionsLiquid0.1~500μmFully automatic, most minimized the operator factors, with very easy operation.
LS-pop(6)Powders, suspensionsLiquid0.2~500μmBasic cost effective instrument with well developed technology
LS-pop(8A)Powders, suspensionsLiquid0.2~500μmBasic cost effective instrument with well developed technology
LS608Powders, suspensionsLiquid0.1~500μmWith the same measuring range as Easysizer20
LS908Powders, suspensionsLiquid0.05~500μmThe only effective instrument with lower limit of submicron made in China(D50<1μm)
LS-CWM(3)Powders, suspensionsLiquid0.5~1500μmMeasurement of coarse(D50>100μm) and wide distribution samples, suitable for coal slurry etc.
LS-C(III)Powders, suspensionsLiquid, Air0.1~1000μmMeasurement of samples that cannot be dispersed in liquid; wet dispersion is optional for this model.
DP-02PFog drops1.0~1500μmFor the measurement of fog drops
RC-3000Powers

Suspensions

1.0~256μm

Suitable for high resolution samples, such as copy powder, micro-abrasives; Or for liquids with few particles such as particles in river water.

RC-2100Powers

Suspensions

1.0~256μm
PIP9.1Powers

Suspensions

0.5~3000μmObserve the particle images besides of particle size distributions, a good assistant instrument for particle size analysis.

Light Scattering Phenomena

Light will departure from its original traveling direction when met particles. Large particles generate small scattered angles (figure A), small particles generate large scattered angles (figure B). The larger of the angle scattered lights detected, the lower measurement range will be realized.

Optical Structure

Laser particle size analyzer is an optical instrument in nature. We have developed the Integrated Laser Emitter, Trapezoid Measurement Cell, multiple patents such as scattered light Detection Around a Sphere surface (DAS), scattered light Detection in Two mutually perpendicular Planes (DTP), which have greatly improved the performances of the laser particle size analyzers.

Scattered light Detection Around a Sphere surface (DAS) :

The simple optical structure (spherical layout of large angle light detectors) solves the accurate focusing of large angle scattered light.

Scattered light Detection in Two mutually perpendicular Planes (DTP)

On the premise of stable total laser output, random fluctuation of large angle scattered light still exists. This is due to the emulative character of the polarized light(large angle-scattered light is partially polarized).

The patent is to receive the scattered light on two mutually perpendicular surfaces, the average value of the two received light intensities represents the light intensity of the scattering angle. This can significantly reduce the scattered light intensity fluctuations.

Calculation of Scattered Light Energy:

The calculation of scattered light energy is the foundation for getting accurate size distribution. The instruments adopt full Mie theory and can measure particles from submicron to one thousand microns.

Light energy data reversal models:

Rosin-Rammler(single peak wave distribution)and poly-peak wave distribution to meet different needs of users.

Software:

User friendly interface, detailed and flexible data output, different data formats, remote service function.

LS-POP6 EASYSIZER20

DP-02P Laser Particle Size Analyzer suppliers    DP-02P Laser Particle Size Analyzer manufacturers