Quick Brief

Place of Origin: Shandong China (Mainland) Brand Name: CHEMINS Model Number: DO4100S Response time: <60 seconds (the 98% of final va... Operating Temperature: 0-60C Power input: AC220V 50Hz Degree of protection: IP65 Weight: 1.2kg Dimensions: 146*146*108

Product Features:

portable dissolved oxygen analyzer

operatingtemperature:0~60c

degree of protection:IP65

dimensions :146*146*108

Business Terms:

Port: Qingdao

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 999 Unit/Units per Month

Payment Terms: T/T

Contact Supplier
DO4100S Dissolved Oxygen Controller (portable dissolved oxygen analyzer)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

DO4100S Microcomputer Dissolved OxygenController

Application

Widely used in online dissolved oxygen monitoring for power plant, chemical, industrial wastewater, pharmaceutical, biochemical and water treatment industry.

Feature

l With high precision AD converter and micro-processor technology.

l Dissolved oxygen and temperature measurement are simultaneously. Automatic temperature compensation.

l Using the advanced devices, dual high-impedance input up to 1012Ω, strong anti-jamming capability.

l Optocoupler isolated output. No interference between input sensor signal and output signals. Remoste transmission is available.

l LED display in English. Waterproof and dustproof design, suitable for outdoor mounting.

l Digital interface can be easily linked into the computer for monitoring and communication.

Specification

Measuring rangeO2: 0~100.0 ug/L 0~20.00 mg/L

Temperature: 0.0~99.9°C

Resolution0.1 ug/L 0.01 mg/L

Temperature: 0.1°C

AccuracyO2: 0.1ug/L±1Digit

Temperature: 0.1°C±1Digit

Response time<60 seconds (the 98% of final value, 25°C)
Operating Temperature0~60°C
Input impedance≥1012Ω
Temperature compensationAuto and manual temperature compensation is selectable.

2 types of auto temperature compensation: PT1000, NTC2.252K.

Analog outputIsolated 0 ~ 10mA output (load <1.5 kΩ) or:

Isolated 4 ~ 20mA output (load <750 Ω)

Relay OutputHigh point, low points and delay are all programmable;

Two sets of ON / OFF output; AC220V maximum current of 3A.

Communication interfaceRS485 or 232 (optional)
Power inputAC220V±22V ,50Hz±1Hz
Solution groundWith electrode diagnostics to eliminate the interference of solution.
Degree of protectionIP65
Weight1.2kg
Dimensions146×146×108 mm(H×W×D)