1)Static single phase energy meter
2)Good price and quality
3)CE,ISO9001:2008,IEC62053-21
4)Suitable for Asia-east market
Port: Ningbo
Minimum Order Quantity: 200 Piece/Pieces
Supply Ability: 30000 Piece/Pieces per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union
Contact SupplierPackaging Detail: Standard export packing:Foam+carton
Delivery Detail: 30days after advance deposit
Brief Product introduction
DDS5558 Static single phase energy meter wireless is a kind of induction type meter,which is applicable to measure the rated frequency 50Hz and power loss in electrified-wire netting. The meter has novel design, rational structure and features of high
overload, low power loss and long life etc.
Scope of application
Single phase electronic energy meter is suitable for measuring single phase AC active energy consumption in rated frequency 50HZ. It is installed indoors, which temperature is in -35~+60°C and the relative humidity shall exceed 95%,and the air should not be included some harm gas, hust, mildew, and insect, etc.
Function and features
2.1 Sub-closed iron core
2.2 The die-casting frame is made of alloy aluminum, to assure the magnetic line stably and reliably.
2.3 Meter bearing has three kinds, may select dual jewel, magnetic thrust or magnetic float;
2.4 May select 5+1 digits or 5 digits register;
2.5 May select 5 kinds of cases: bakelite, PC, ABS plastic, glass and aluminum.
Main technical data
Type | Accuracy | Rated voltage (V) | Rated current (A) | Overload capacity | Starting current | Insulation performance |
DDS5558 | 1 or 2 | 220-240 | 2.5(10),5(20),5(30),10(40), 15(60) | 4~6Ib | 0.5%Ib | AC volation 2kV 50V 1 min impulse voltage 6kV |
Transport and storage
1 Transport and storage of the meter must not be shaken and must accord with stipulated IEC61036 or IEC62053-21.
2 The meter must be stored in the original packing box and the environmental temperature is in -25°C~+70°C, relative humidity shall exceed 95%, and there is not any corrosive gas. The ambient temperature shall not vary violently.
3 The meters should be in the original packing box and the boxes should be piled up no more than five cartons on the rack. The separate meters should be piled up no more than five pieces. The unpacked meter is not suitable for storage.
Maintenance and service
Within 18 months from the date of manufacture the use complies with all of above rules, if the meter still being sealed does not confirm to any technical requirements of IEC61036 or IEC62053-21, or of any certification of power department of measuring department, the manufacture guarantees to repair freely or to change.