Compact type pressure transmitter
1. Power voltage: (12 to 45) V DC
2. Accuracy grade 0.1 grade, 0.2 grade, 0.5 grade
Minimum Order Quantity: 1 Piece/Pieces other
Supply Ability: 1000 Piece/Pieces per Month
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Standard package
Delivery Detail: 7 days after payment
Pressure transmitterCompact type pressure transmitter
Mainly technical parameters
1. Good reliability, high precision
2. Temperature influence slightly
3. Stability ±0.1%FS / year
4. Intelligentize, miniaturization
5. Control parameter is locked by cipher code so that be ensure the safety.
6. Wide measuring scope
7. Display for LCD digital range or percentage
8. Software compensation
9. When the range is changed, it may not introduce pressure.
10. Self-diagnosis in the failure, remote setting communication, remote control
11. Waterproof, dust--proof, shake--proof, explosion--proof, corrosion--proof
12. Field bus HART protocol communication
Technical parameters
Measuring range: Relative pressure max 0~60 MPa min 0~1.6 KPa
Absolute pressure max 0~60 MPa min 0~20 KPa
Negative relative pressure ( –0.1~2) MPa
Power voltage: (12~45) V DC
Communication output Communication distance: 2 km, using CEV cable
Load capacitance: below 0.22μF
Load inductance: below 3.3 mH
Space with power line: above 15 cm
Input impedance of the receiving instrument which connected on the receiving resistance: when 2.4 KHz above 10 kΩ
Accuracy: Accuracy grade 0.1 grade, 0.2 grade, 0.5 grade
Temperature influence: ±0.15%FS / 10°C
Stability better than 0.1% FS/year
Position influence: Installation position not affect zero point
Permission temperature: Normal working temperature: -20°C~70°C
Membrane: -20°C~80°C (short-time may reached 130°C)
Storage temperature: -20°C~80°C
High-low temperature type: -65°C~150°C 10°C~200°C 10°C~350°C
Relative humidity: 0~100% RH
Explosion-proof grade: Isolated explosion type ExdIIBT5 or ExdIICT6
Protection grade: IP67
Material of part contacted with measured medium:
Process connection element: 316 L/304/1Gr18Ni9Ti stainless steel /Hutchinson Alloy C
Seal element: fluorine rubber/Nitrile rubber/PTEE/full sealing weld
Lead-out mode of wiring: may be lead-out from any outlet according to the requirement, it is advised to use min φ7.5 industrial cable as lead so as to be sealed. Lead-out joint selected universal cable joint, without lead end should be sealed with end cover.
Field indicating: LCD liquid crystal digital display (option)
External adjustment zero: Resolution 0.05% of the range, is setting within measuring scope
tehcni