Home  >  Other Measuring & Analysing Instruments

Common Heat Energy Meter DN20 - RLB(DN20)

1.Measure heat power passed through pipes, 2.Latest patent technique, 3.Update online, 4.Data backup and automatic correction - more info check here: http://www.buymeasuringtools.com/Common-Heat-Energy-Meter-DN20-10325870/

Quick Brief

Place of Origin: Henan China (Mainland) Brand Name: SUNTRONT Model Number: RLB(DN20) Min Flow Rate: 50L/h Max Flow Rate: 5000L/h Common Flow Rate: 2500L/h Min Temperature Difference: 1 or 3 Celsius Max Temperature Difference: 90 Celsius Min Display Temperature: 0.1 Celsius Static Working Current: < 7μA Battery Service Life: > 5 years Digit Number of LCD: 8 numbers Pressure Resistance: 1.6MPa

Product Features:

1.Measure heat power passed through pipes

2.Latest patent technique

3.Update online

4.Data backup and automatic correction

Business Terms:

Port: Qingdao / Tianjin

Minimum Order Quantity: 500 Piece/Pieces

Supply Ability: 600000 Piece/Pieces per Year

Payment Terms: L/C,T/T,To be negotiated

Contact Supplier
Common Heat Energy Meter DN20
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: In cartons

Delivery Detail: 20-35 days(Subject to technical requirement and amount of order)

Specifications and Product Details:

General Instruction

Common Heat Energy Meter can measure heat power passed through pipes. It consists of flow sensor, microprocessor and temperature sensor. Microprocessor obtains flow signals through flow sensor and signals of water temperature at the entrance or exit by temperature measuring circuit, and then it will calculate the released heat power by heat-carrying liquid according to the standard of heat calculation formula. It also can be used to measure cold power if connect temperature sensors reversely.

Characteristics

1. Latest patent technique of wireless digital monitoring to supervise and calculate heat power.

2. No mechanic gears, no magnetism sensor, wear resistance, anti-corrosive and anti-attack.

3. Alarming when low voltage.

4. Alarming when temperature sensor is disconnected or in case of short circuit.

5. Flow has 8 levels and can be separately adjusted automatically, high accuracy.

6. Smart lower power consumption according to flow speed.

7. Update online.

8. Data backup and automatic correction.

9. Ultra-low energy consumption.

Standard

European Standard EN1434 and 01ML-R75 International Standard

CJ128-2000 Heat Meter Issued by State Construction Department of China

Technique Specifications

Flow Sensor

Caliber

Common Flow Rate

Min Flow RateMax Flow Rate
15mm

1500L/h

30L/h3000L/h
20mm

2500L/h

50L/h5000L/h
25mm

3500L/h

70L/h7000L/h

Min Flow Rate for Display: 0.01m3(working state) 0.00001m3(testing state)

Min Heat Power for Display: 1kWh (working state) 0.001kWh (testing state)

Working Condition of Temperature Sensor

Min Temperature Difference

1 or 3 Celsius

Max Temperature Difference

90 Celsius

Min Display Temperature

0.1 Celsius

Static Working Current

< 7μA

Battery Service Life

> 5 years

Digit Number of LCD

8 numbers

Max Accumulated Working Time

4.2x109hours (Meter only displays final 8 numbers when accumulated working time is more than 99999999 hours)

Max Accumulated Flow Rate

4.2x109m3(Meter only displays final 8 numbers when accumulated flow rate is more than 999999.99m3)

Accuracy

GradeB or GradeC

Pressure Resistance

1.6MPa

Pressure Loss

≤0.025MPa

Picture for reference

Model

RLB---common heat meter, LCD display, DN15/20/25

Common Heat Energy Meter DN20 suppliers    Common Heat Energy Meter DN20 manufacturers