Home  >  Flow Measuring Instruments  >  Flow Meters

Clamp-on mounting type,Doppler Clamp-on ultrasonic flowmeter(for dirty liquids) - DMDFB

1.Suitable for dirty liquids measurement, 2.High temp.:280, 3.Very low flow rate measurement:0.03m/s, 4.High accuracy(2%) - more info check here: http://www.buymeasuringtools.com/Clamp-on-mounting-type-Doppler-Clamp-on-ultrasonic-flowmeter-for-dirty-liquids-10018806/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: DYNAMETERS Model Number: DMDFB Principle: Doppler ultrasonic Mounting type: Clamp-on Accuracy: 0.5%~2.0% F.S

Product Features:

1.Suitable for dirty liquids measurement

2.High temp.:280

3.Very low flow rate measurement:0.03m/s

4.High accuracy(2%)

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 500 Set/Sets per Month

Payment Terms: T/T

Contact Supplier
Clamp-on mounting type,Doppler Clamp-on ultrasonic flowmeter(for dirty liquids)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Carton as per export standard.

Delivery Detail: Within 7 workdays.

Specifications and Product Details:

Principle of Measurement:

The Doppler ultrasonic flow meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be filled full of liquids, there must be Ta certain amount ofT air bubbles or suspended solids in liquid.

Transducers are clamp-on or hot-tapped probe types, user don’t need to shut down the pipe flow when install the clamp-on transducers.

The flow meter operates by transmitting an ultrasonic sound from its transmitting transducer, the sound will be reflected by useful sonic reflectors suspended within the liquid and recorded by the receiving transducer. If the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted (Doppler frequency) from the transmitted frequency. The shift in frequency will be directly related to the speed of the moving particle or bubble. This shift in frequency is interpreted by the instrument and converted to various user defined measuring units.

Features of the clamp-on series Transit-time ultrasonic flowmeters:

1,Suitable to measure the flow of solids-bearing or aerated liquid within closed conduit

2,Automatically signal gain adjustment

4,Don't need to shut down the pipe .

5,Flow on when install the transducers.

6,User-friendly configurations.

7,4-20mA and totalizer pulse output

8,Accuracy: 2.0% Calibrated span

Main advantages of the ultrasonic water flow meter:

1.Measurable to fluid of very low flow rate, low to 0.10FPS (0.03M/S).

2.Non-invasive, Standard transducer fit to 1~160 inches (DN25~4064MM), Round-Hoop type, 1/2~2 inches available.

3.Standard temperature transducer :-40~+120 °C;

4.Magnetic force mounting type transducers also is available.

5.High temperature transducer :-40~+280 °C

Applications of the Clamp-on ultrasonic flow meter:

1.Waste water

2.Sewage,

3.Paper pulp,

4.Ore pulp,

5,Effluent,

6.HVAC,etc.

More details of the ultrasonic flow meter ,welcome to our website:www.dynameters.com

Technical Parameters of the water flow meter:

CE Certificate of the Clamp-on series Doppler Ultrasonic flow meter

Clamp-on mounting type,Doppler Clamp-on ultrasonic flowmeter(for dirty liquids) suppliers    Clamp-on mounting type,Doppler Clamp-on ultrasonic flowmeter(for dirty liquids) manufacturers