Home  >  Pressure Measuring Instruments  >  Pressure Transmitters

Ceramic Pressure Transmitters 130C(I) - 130C(I)

Ceramic Pressure Transmitters 130C(I) - more info check here: http://www.buymeasuringtools.com/Ceramic-Pressure-Transmitters-130C-I-10336629/

Quick Brief

Place of Origin: Belgium Brand Name: BCM sensor Model Number: 130C(I) Model Number: 130C Brand Name: BCM Place of Origin: Belgium technology: thick-film ceramic output signal: 4~20 mA, 0~5 V or 0~10 V measuring accuracy: 0.25%fso, 0.5%fso (standard... environment protection: IP 65 (connector), IP 6...

Product Features:

Ceramic Pressure Transmitters 130C(I)

Business Terms:

Port: Xi'an

Minimum Order Quantity: 5 Piece/Pieces

Payment Terms: T/T

Contact Supplier
Ceramic Pressure Transmitters 130C(I)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard package. one box contains 1pc prodcut with testing data.

Delivery Detail: In 30 days after receipt of your order.

Specifications and Product Details:

Ceramic Pressure Transmitters 130C(I)

Based on thick-film ceramic technology, BCM model 130C ceramic pressure transmitter is designed for use in applications which deal with corrosive pressure media and require high accuracy. The pressure diaphragm of this transmitter is made from ceramic (Al2O3) material, while its wetted parts are made from either 316L stainless steel, or PVDF which possesses a higher degree of resistance against chemical corrosion.


130C transmitters are manufactured to be able to measure either gauge pressure (G) or absolute pressure (A). Two types of procession connections are available for 130C transmitters: inner cavity type (type I) and semi-flush type (type II). Type I can be used to measure gases or dilute liquids, while type II can measure viscous fluids or fluids with grains.


The output signals of 130C pressure transmitters are configured to meet the need of different controllers used in industrial automation processes, including 4~20 mA, 0~5 V and 0~10V. With 130C one can obtain 0.25 %fso accuracy in measurement with long-term stability better than 0.15 %fso/year. The zero thermal drift is less than 0.04 %fso/°C, while the sensitivity thermal drift is 0.02 %fso/°C over the whole operating temperature range.

Features:

1. high resistance against chemical corrosion
2. semi-flush membrane available (type II)
3. various pressure ranges & type:
gauge: -1~0.5 bar, ..., 0~600 bar
absolute: 0~0.35 bar, ..., 0~20 bar
4. output signal: 4~20 mA, 0~5 V or 0~10 V
5. measuring accuracy: 0.25%fso, 0.5%fso (standard)
6. materials of pressure membrane: ceramic (Al2O3)
wetted parts: 316L SS, option: PVDF
housing: 304 SS (standard)
7. environment protection: IP 65 (connector), IP 66 (direct cable)
8. medium temperature: up to 125 °C

Specification:

measuring media

type Iliquids which are compatible with 316LSS
type IIviscous fluids or fluids with grains, which are compatible with 316L SS

measuring ranges

bar (G,SG)*0~0.5, 0~1, 0~2, 0~5, 0~10, 0~20, 0~50, 0~100, 0~400, 0~600
bar (A)0~0.35, 0~0.5, 0~1, 0~2, 0~5, 0~10, 0~20
overload pressure%FS200 (for 400 bar and 600 bar, it is 650 bar and 880 bar, respectively)
burst pressure%FS250 (for 400 bar and 600 bar, it is 650 bar and 880 bar, respectively)
power supplyVdc24 (recommended), 12, ..., 36
output signal4~20 mA, 0~5 V, 0~10 V
zero offset%FSO1 maximum
accuracy%FSO±0.25,±0.5(standard)
long-term stability of zero%FSO/year0.15

Load resistance

Ω

250~1150Ω (for 4~20 mA current loop)
> 5000Ω (for voltage output)
storage temperature range-40~+85
operating temperature range-40~+125
compensated temperature ranges-20~+80
temperature coefficient of ZERO%FSO/±0.02
temperature coefficient of SPAN%FSO/±0.04

process connection

thread

G1/4, male (type I)
G1/2, male (type II)
other thread available upon request
electrical connectionconnector, cableDIN 43650 connector (standard), plug-in connector; shielded PVC cable
environment protectionIP ratingIP 65 (connector); IP 66 (direct cable)
pressure membrane materialceramic (AlO3)
material of wetted parts316L SS (standard), option: PVDF
housing material304 SS

How to order: model - range & type - output - accuracy-process connection, material - electrical connection- customer specific requests (if any)

Ordering Code example: 130C(type II)-20barA-4/20mA-0.25%fso-G1/2, PVDF-DIN43650