Ceramic Pressure Transmitter Model 131C
Port: Xi'an
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 1000 Piece/Pieces per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: standard package. each package contains 2pcs products with testing data.
Delivery Detail: 30 days after receipt of your order.
1301 transmitters are manufactured to be able to measure either gauge pressure (G) or absolute pressure (A). Two types of procession connections are available for 1301 transmitters: inner cavity type (type I) and semi-flush type (type II). Type I can be used to measure gases or dilute liquids, while type II can measure viscous fluids or fluids with grains.
Features:
1. high resistance against chemical corrosion
2. semi-flush membrane available (type II)
3. various pressure ranges & type:
gauge: -1~0.5 bar, ..., 0~600 bar
absolute: 0~0.35 bar, ..., 0~20 bar
4. output signal: 4~20 mA, 0~5 V or 0~10 V
5. measuring accuracy: 6. materials of pressure membrane: ceramic (Al2O3)
wetted parts: 316L SS, option: PVDF
housing: 304 SS (standard)
7. environment protection: IP 65 (connector), IP 66 (direct cable)
8. medium temperature: up to 125 °C
Specification:
measuring media | type I | liquids which are compatible with 316LSS | |
type II | viscous fluids or fluids with grains, which are compatible with 316L SS | ||
measuring ranges | bar (G,SG)* | 0~0.5, 0~1, 0~2, 0~5, 0~10, 0~20, 0~50, 0~100, 0~400, 0~600 | |
bar (A) | 0~0.35, 0~0.5, 0~1, 0~2, 0~5, 0~10, 0~20 | ||
overload pressure | %FS | 200 (for 400 bar and 600 bar, it is 650 bar and 880 bar, respectively) | |
burst pressure | %FS | 250 (for 400 bar and 600 bar, it is 650 bar and 880 bar, respectively) | |
power supply | Vdc | 24 (recommended), 12, ..., 36 | |
output signal | 4~20 mA, 0~5 V, 0~10 V | ||
zero offset | %FSO | 1 maximum | |
accuracy | %FSO | ±0.25,±0.5(standard) | |
long-term stability of zero | %FSO/year | 0.15 | |
Load resistance | Ω | 250~1150Ω (for 4~20 mA current loop) | |
> 5000Ω (for voltage output) | |||
storage temperature range | -40~+85 | ||
operating temperature range | -40~+125 | ||
compensated temperature ranges | -20~+80 | ||
temperature coefficient of ZERO | %FSO/ | ±0.02 | |
temperature coefficient of SPAN | %FSO/ | ±0.04 | |
process connection | thread | G1/4, male (type I) | |
G1/2, male (type II) | |||
other thread available upon request | |||
electrical connection | connector, cable | DIN 43650 connector (standard), plug-in connector; shielded PVC cable | |
environment protection | IP rating | IP 65 (connector); IP 66 (direct cable) | |
pressure membrane material | ceramic (AlO3) | ||
material of wetted parts | 316L SS (standard), option: PVDF | ||
housing material | 304 SS |
How to order: model - range & type - output - accuracy-process connection, material - electrical connection- customer specific requests (if any)
Ordering Code example: 130C(type II)-20barA-4/20mA-0.25%fso-G1/2, PVDF-DIN43650