Home  >  Testing Equipment

CA4810A transisstor curve tracer - CA4810A

*Voltage range: 0 ~ 500V, *Current 0.1 ~ 10. A, *Power resistance: 0 ~ 500k points and 11, *DIMENSION: 341x 510x251mm - more info check here: http://www.buymeasuringtools.com/CA4810A-transisstor-curve-tracer-10247277/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: UF Model Number: CA4810A DIMENSION: 341x 510x251mm Voltage range: 0 ~ 500V

Product Features:

*Voltage range: 0 ~ 500V

*Current 0.1 ~ 10. A

*Power resistance: 0 ~ 500k points and 11

*DIMENSION: 341x 510x251mm

Business Terms:

Port: Shenzhen

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 100 Set/Sets per Day

Payment Terms: T/T,Western Union,MoneyGram,Paypal

Contact Supplier
CA4810A transisstor curve tracer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

CA4810A semiconductor instrument is a kind of tube is shown that with the various characteristics curve of semiconductor devices and measuring instruments, low static parameters. Is engaged in the research and manufacturing of semiconductor tube radio field workers of a kind of indispensable equipment.


Specification:
Vertical shaft deflection coefficient
*The collector range 20uA/DIV ~ 1A/DIV points and 15 gears, error less than ± 3%
*Diode reverse leakage current 0.2 uA/DIV ~ 6 10uA/DIV
*2uA/DIV ~ 10uA/DIV, error less than ± 3%
*UA/DIV 1uA ~ 0.2 / DIV, less error ± 10%
*2uA/DIV gear than 0.5 V/DIV interference
*Base current source voltage or base 20mV/DIV, error less than ± 3% and deflection magnification (0.5, error less than ± 10%


Horizontal axis deflection coefficient
*The collector voltage range 0.05 V/DIV 50V/DIV points and 10 ~, error less than ± 3%
*Diode leakage current voltage range run at 100V/DIV ~ 500V/DIV points, error less than 3 ± 5% (optional) 5KV high-pressure one,
*Base voltage range 0.05 V/DIV ~ 2V/DIV, 6, error less than ± 3%
*Base current or turn the source voltage.01v/DIV error less than ± 3%


Ladder current
*1uA/level range ladder current 0.1 ~ A/level, points, 16 ± 5% less error
*Step voltage range 0.05 V/level ~ 6, 2V /, error less than ± 5%
*Ω 1k series resistor 10k, Ω 100k, Ω 3 points, and less error of ± 5%
*Each cluster series 4 ~ 10 levels continuously adjustable
*No less than current 1DIV ± ladder
*Second series 200 (minutely for frequency 50Hz)
*Ladder polarity positive or negative
*Ladder continuously or single cluster forms


The collector scanning power
*The power is the maximum current collector scan 0 ~ 5V files: 10
0 ~ 20V files: 2.5
0 ~ run at 100V files: 0.5 A
0 ~ 500V files: 0.1


*Power resistance Ω 500k 0 ~ 11 points
Ω 500k ~ 100 Ω error less than ± 10%
Ω 0.5 ~ 2.5 ± 20% Ω less error


The collector power supply
*Voltage range: 0 ~ 500V
*Current 0.1 ~ 10. A
*Power resistance: 0 ~ 500k Ω points and 11
*Step voltage range: 0.05 V/class/level. 2V -
*Has the dual cluster display function
*Special mosfet matching and test function
5kV pressure


DIMENSION
Length: 341 mm
Width 510 mm
Highly 251 mm
Weight 1.35 Kg

Accessories
User manuals
High-pressure testboard (optional),
power
certificate

CA4810A transisstor curve tracer suppliers    CA4810A transisstor curve tracer manufacturers