Temperature controller have advance microcontroller and firmware design,improved noise immunity.Simple and accurate Self Tuning
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month 1
Payment Terms: T/T
Contact SupplierPackaging Detail: box
Delivery Detail: 1day
Please note that the product that you choose is:
The following are the concise introduction (If you need detail information, please contact us):
Main Features
2. TECHNICAL SPECIFICATION
Input type: (Either of below specifications can be used selectively in the same instrument)
Thermocouple: K, S, E, R, J, T, B, N
Resistance temperature Detector: Pt100, Cu50
DC Voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~20mV, etc
DC current (external shunt resist needed): 0~10mA, 1~20mA, 4~20mA, etc
Optional: apart from the above-mentioned Input type, additional type can be provided upon request. (Graduation index is needed)
Instrument Input range
K(-50--+1300°C), S(-50--+1700°C), R(-50--+1650°C), T(-200--+350°C),
E(0~800°C), J(0--1000°C), B(0--1800°C), N(0~1300°C)
Pt100(-200--+600°C), Cu50(-50--+150°C)
Linear Input: -1999--+9999 defined by user.
Measurement accuracy
0.2%FS: RTD, linear voltage, linear current and input with ice point compensation or Cu50 copper compensation.
0.2%FS±0.2°C: thermocouple input with internal automatic compensation.
0.5%FS: T only
response time ≤0.5s ( when dL=0).
Note: for thermocouple B, the measurement accuracy of ±0.2% FS can be guaranteed when input
range is between 600--1800°C,and not guaranteed when input range is between 0--600°C.
Control mode:
On-off control mode (deadband adjustable)
Tcontroller artificial intelligence control, including fuzzy logic PID control and advanced control algorithm with the function of parameter auto tuning (MPT).
Output mode (modular)
Relay contact discrete output (NO+NC): 264VAC/1A or 30VDC/1A
BCR NO contact discrete output (NO+NC): 85~264VAC/0.2A (continuous), 2A (20mS
instantaneous, repeat period≥5s)
SSR Voltage output: 12VDC/30mA (used to drive SSR).
Linear current output: 0~10mA, 4~20mA (Output voltage greater than 11V)
BCR cross zero trigger output: can trigger TRIAC of 5~500A, two parallel-connected BCR or BCR power module.
Alarm function: upper limit, low limit, positive deviation and negative deviation, selectable using parameters.
Alarm output: 2 modular output.
Manual function: AUTO/MAN bumpless transfer(C18 series only )
Power supply voltage rating: 85-264VAC/50-60Hz.
Power consumption: ≤5W.
Ambient temperature: 0~50°C.
Front panel dimension: 96X96mm, 160X80mm, 80X160mm, 48X96mm, 96X48mm.
Panel cutout dimension: 92X92mm, 152X76mm, 76X152mm, 45X92mm, 92X45mm.
Parameter Setting Flow Chart:
3.FRONT PANEL AND OPERATION:
Details photo of temperature controller: