Digital PID temperature controller
-199-1250C range temperature controller
TC/RTD input thermostat
CE certificate
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month 1
Payment Terms: T/T
Contact SupplierPackaging Detail: box
Delivery Detail: 1day
C18 defrost temperature controller
1.1 Main feature.
1.2 Model definition.
Advanced modularized hardware design is utilized for C18 series instruments. There are maximum five module slots: output, alarm, communication and other functions can select the appropriate module on demand. The modules can be purchased together or individual, and can be assembled freely. The input type can be set to thermocouple, RTD, or linear current/voltage. The ordering code of C18 series instrument is made up of 9 parts. For example:
It shows that the model of this instrument is C18, front panel dimension is A size(96 ×96mm), no module is installed in MIO slot, linear current output module is installed in OUTP (main output), ALM (alarm) is L5 (dual relay contact output module), no module is installed in AUX (auxiliary output), S4 (RS485 communication interface module) is installed at COMM , and the power supply of the instrument is 24VDC, an extended input type (F2 radiation type pyrometer) is available
2. TECHNICAL SPECIFICATION OF TEMPERATURE CONTROLLER.
Input type: (Either of below specifications can be used selectively in the same instrument)
Thermocouple: K, S, E, R, J, T, B, N
Resistance temperature Detector: Pt100, Cu50
DC Voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~20mV, etc
DC current (external shunt resist needed): 0~10mA, 1~20mA, 4~20mA, etc
Optional: apart from the above-mentioned Input type, additional type can be provided upon request. (Graduation index is needed)
Instrument Input range
K(-50--+1300°C), S(-50--+1700°C), R(-50--+1650°C), T(-200--+350°C),
E(0~800°C), J(0--1000°C), B(0--1800°C), N(0~1300°C).
Pt100(-200--+600°C), Cu50(-50--+150°C)
Linear Input: -1999--+9999 defined by user.
Measurement accuracy
0.2%FS: RTD, linear voltage, linear current and input with ice point compensation or Cu50 copper compensation.
0.2%FS±0.2°C: thermocouple input with internal automatic compensation.
0.5%FS: T only
response time ≤0.5s ( when dL=0).
Note: for thermocouple B, the measurement accuracy of ±0.2% FS can be guaranteed when input
range is between 600--1800°C,and not guaranteed when input range is between 0--600°C.
Control mode:
On-off control mode (deadband adjustable)
Tcontroller artificial intelligence control, including fuzzy logic PID control and advanced control algorithm with the function of parameter auto tuning (MPT).
Output mode (modular)
Relay contact discrete output (NO+NC): 264VAC/1A or 30VDC/1A.
BCR NO contact discrete output (NO+NC): 85~264VAC/0.2A (continuous), 2A (20mS
instantaneous, repeat period≥5s)
SSR Voltage output: 12VDC/30mA (used to drive SSR).
Linear current output: 0~10mA, 4~ 20mA (Output voltage greater than 11V)
BCR cross zero trigger output: can trigger TRIAC of 5~ 500A, two parallel-connected BCR or BCR power module.
Alarm function: upper limit, low limit, positive deviation and negative deviation, selectable using parameters.
Alarm output: 2 modular output.
Manual function: AUTO/MAN bumpless transfer(C18 series only )
Power supply voltage rating: 85-264VAC/50-60Hz.
Power consumption: ≤5W.
Ambient temperature: 0~50°C.
Front panel dimension: 96X96mm, 160X80mm, 80X160mm, 48X96mm, 96X48mm
Panel cutout dimension: 92X92mm, 152X76mm, 76X152mm, 45X92mm, 92X45mm.
Parameter Setting Flow Chart:
4.FRONT PANEL AND OPERATION:
Details photo of temperature controller: