Measuring Tools
Measuring Tools Business Opportunities &  Manufacturers B2B

Buy Lead: JC-605 digital temperature controller (See details)

How can I ger Jc-605 temperature controller manual?Thank you >> More queries...

Posted By: Mehmet on September 12, 2019 55:16 From 1.132.106.***Inquiry Related Cateogry: Temperature Instruments

Suppliers can follow up instruction to get this buyer's email address and other contact information.

Inquering Related Product: JC-605 digital temperature controller - JC-605

Quick Brief

Place of Origin: Guangdong China (Mainland)Brand Name: juchuangModel Number: JC-605
Usage: temperature controllerTheory: Temperature Controller 

Product Features:

digital temperature controller

1.Temperature display (Celsius/Fahrenheit degrees)

2.Temperature control

Product Cateogry: Temperature Instruments

Business Term:

Port: Zhongshan

Minimum Order Quantity: 500 Unit/Units

Supply Ability: 99999 Unit/Units per Month

Payment Terms: T/T

 
Contact Supplier
JC-605 digital temperature controller

Packaging Information

Packaging Detail:Colour box& carton.
Delivery Detail:2 weeks upon receipt of the whole payment

Specifications and Product Details:

Original Product Page
temperature controller
·Temperature display (Celsius/Fahrenheit degrees)
·Temperature control
·Evaporator fan control (Parallel with compressor or continuous running changes)
·Manual, automatic defrost by electric heater or hot gas
·Time or temperature setting to end defrost
·The cold-room sensor temperature can lock during defrost
·Parameter sets and value storing
·Compressor re-starts delay
·Parameter locking
·The factory default resumption
·Offset on sensor temperature ·Self testing
·Power supply12V50/60Hz
·Power consumpotio n5W
·Output relay for compressorN.O.30A/250V~50/60Hz
·Output relay for defrostN.O.30A/250V~50/60Hz
·Output relay for fan: N.O.30A/250V~50/60Hz
·Temperature sensorNTC,2 sensorTemp. Display , defrost control
·Temperature unit/Change
·Resolution1
·Accuracy±1±2
·Range of temperature control-45 ~ 45-40 ~ 120
·Panel dimension78×35×37mm·Mounting hole dimension71×29mm
Parameter
Function
Set range
Default
PA
Menu password
00 ~ 99
00
E1
Lower set point limit
-45 ~ Set temperature
-30
-40 ~ Set temperature
-22
E2
Higher set point limit
Set temperature ~ 45
-15
Set temperature ~ 120
05
E3
Temperature hysteresis
01 ~ 10
05
01 ~ 36
07
E4
Comp. Start delay time
00 ~ 10Min
00
E5
Offset on room temp.
-05 ~ 05/
00
E6
Offset on evep. temp.
-05 ~ 05/
00
F0
Defrost function
00=Electric heater
01
01=Hot gas
F1
Max. Defrost duration
01 ~ 60 Min
20
F2
Defrost interval time
00 ~ 24Hr
06
F3
Defrost termination temp.
00 ~ 45
04
32 ~ 110
39
F4
Display during defrost
00=Normal display
01
01=Last value before defrost
F5
Fan operating function
00=Parallel with compressor
00
01=Continuous running (except defrost)
F6
Draining time
00 ~ 20 Min
02
F7
Mode of fan restarts
after defrost
00=Restarts delay after comp. reworking time (F8)
00
01=Restarts when evaporator temp. at F9.
F8
Restarts delay time (F7=00)
00 ~ 20 Min
02
F9
Restarts subject to evap. Temp. (F7=01)
-20 ~ 20
-08
-04 ~ 68
18
C1
Temperature unit
00=
00
01=
CPA
Changing menu password
00 99Setting00, the menu password is cancelled
00
Notes:
·The parameter can be changed only after the correct PA to be entered, or it can only be checked, except temperature controlling.
·It means locking cancelled if PA is set 00, no password required for checking and/or changing.
·When F7is set 00, F8 parameter is available, F9 is unavailable. When F7 is set 01, F8 parameter is unavailable, F9 is available.

 
Contact Supplier