1.Manufacturer
2.Prompt delivery
3.LCD touch screen
4.Tecumseh compressor
5.Size can be customized
Port: shenzhen
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 100 Set/Sets per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Strong wooden carton
Delivery Detail: 10-15 working days after confirmed
materials,etc
Climatic Hot Boxes
Specifications:
*Model: YTH-1000
*Internal Size(mm)W×H×D: 1000×1000×800
*External Size(mm)W×H×D: 1450×1900×1550
*Temperature Range: -73°C to +180°C
*Humidity Range: 20% ~98%
*Temp.&Humi. Accuracy: ±0.2°C, ±2.5%RH
*Temp.&Humi. Regularity: ±0.5°C, ±4.0%RH
*Indication Resolution: 0.01°C,0.01%RH
*Heating-up time(20°C~HT): 100°C 30mins / 150°C 40mins
*Temp. Down time(20°C~LT):0°C 25mins / -20°C 40mins/-40°C 65mins / -60°C 75mins/-70°C 85mins
*External Material: Stainless steel plate+Powder Coated
*Internal Material: SUS#304 stainless steel plate
*Insulation: PU & Fiberglass wool
*Circulation System: Centrifugal fan
*Heating System: SUS#304 stainless steel high-speed heater
*Humidifying System: Surface evaporating system
*Cooling System: Airtight compressor+finned vaporator+air-cooling condenser
*Dehumidifying System: ADP Critical dewpoint cooling/dehumidifying method
*Controller System: Digital electronic indicator+S.S.R.With PID automatic calculation capability
*Accessories: Viewing window, Shelves (freely adjustable 2 pcs.), Cable port(Ø60mm)Chamber lamp.
*Safety Devices: Non fuse breaker, refrigerator over load relay, Refrigeration high pressure switch, Over Temp. protector, Protection relay, Protection fuse, Water Lever protector, Overheat protector, Alarm
*Power(K.W.): AC 1Ψ 220V,3Ψ380V 60/50Hz
Climatic Hot Boxes
Features:
1. The separation of humidifier system from electric circuit improves safety and protects the circuit against the leakage of water supply line.
2. LCD touch screenAvailable in English, easy operation and program.
3. Can display the relative date of the whole operating system in running mode. Graphic display, precautions, maintenance and troubleshooting appear on the screen instantly.
4. The centrigugal fan provides greater cyclic airflow to avoid dead corner in the chamber so as to obtain an uniform distribution of temperature and humidity.
5. The system of heating up, heating down, dehumidifying, and humidifying can be operated independently to reduce the cost of testing, extend the operation life of the machine and decrease the failure rate.
6. Water supply adopts automatic watering system, circulating water supply together with water filter.