Home  >  Electrical Instruments  >  Battery Testers

BTS-5V20A battery testing machine - CT-3008W-5V20A-T

1)BTS-5V20A battery testing machine, 2)constant-voltage source - more info check here: http://www.buymeasuringtools.com/BTS-5V20A-battery-testing-machine-10127536/

Quick Brief

Place of Origin: Shandong China (Mainland) Brand Name: Gelon China Model Number: CT-3008W-5V20A-T ISO9001:2000: ISO14001:2004

Product Features:

1)BTS-5V20A battery testing machine

2)constant-voltage source

Business Terms:

Port: shenzhen

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 50 Set/Sets per Month

Payment Terms: L/C,T/T,Western Union,MoneyGram

Contact Supplier
BTS-5V20A battery testing machine
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard packing

Delivery Detail: within one month

Specifications and Product Details:

BTS-5V20A Battery Testing machine
Technical Parameters

1,Equipment Comprehensive Performance

1.1Hardware Features According to the international standard design, each channel of the system has an independent constant-current source and constant-voltage source The internal electrical power supply uses the high efficiency switching power supply, the energy conservation effect is remarkable, each power tube has the independent protection circuit, guarantees the Equipment works with safety and reliability. Measure adopts four wire method, decrease contact error, increase measure precision. Each channel is independent; With high efficient cooling system, Equipment can work 24 hours with full load. Hardware adopts double loop control,can change from constant current to constant voltage without pinnacle,protect battery.

1.2Software Features Each channel can program and test independently, after any “stop”, (including power failure) the work step has “continue” function, prevents the current data loss Upper machine is compatible, can suit different versions of lower machine, and has the friendly man-machine interaction contact surface, ease of operation. High speed data acquisition, catches the change detail of voltage and current precisely (16bit AD), with journal function.Formidable data and curve processing function; perfect report form function, supports four kind of report form types and sorts of report formats: Formidable data and curve processing function; perfect report form function, supports four kind of report form types and sorts of report formats: Sees namely the obtained report form: The data obviously derives. Conventional report form: Derives the entire NDA data file Lamination report form: The circulation level, the work step level, the record level data derives separately Definition report form: The user can define and derives the template of the report form The data and the curve may derive to EXCEL, TXT, can be edited and processed

2.1,Technical Parameters

Input powerAC 220 V ±10% / 50 Hz
AD,DAResolutionAD:16bit DA:14bit
Input Resistance≥1MΩ
VoltagePer Channel Voltage RangeCharge0V-5V;Discharge2.5V-5V
Stability±(0.05% of reading + 0.1% of range)
Resolution1/16384*range(5V)
Stability≤0.1%
CurrentPer Channel Current RangeCharge0A-20A;Discharge0A-20A
Accuracy±(0.05% of reading + 0.1% of range)
Resolution1/16384*range(20A)
Stability≤0.1%
PowerPer Channel Output Power800W
Stability≤0.1%
TimeCurrent Response Time≤50ms
Step Time Range>1000h/step
Stability≤0.1%
Data RecordingRecord ConditionΔt:(1~60000S)ΔV:(5mV~5V) ΔI:(20mA~20A)
Record Frequency1Hz
ChargeCharge Mode

Constant Current Charge,Constant Voltage Charge,

Constant Current and Constant Voltage Charge
End ConditonVoltage,Current,Relative Time,Capacity
DischargeDischarge ModeConstant Current Discharge
End ConditionCurrent,Current,Relative Time,Capacity,
CycleLoop Measure Range1-9999times
Per Loop Step No.64
Nested LoopNested loop Function,Max Support 3 Layers
ProtectionSoftware ProtectionPower-down Data Protection , Off-line Testing Function , Setting Protection Condition,Setting Parameter:Voltage Low limit,Voltage Upper limit,Current Low limit,Current Upper limit,Delay Time
Hardware ProtectionAddition Avoiding Reverseconnection Protection Model
Voltage and Current Testing Sample4-wire connecting
Noise<65DB
DatabaseMy SQL Databace
A Means of Communication of Upper MachineTCP/IP
Data OutputEXCEL,TXT,Graph
Communication InterfaceEthernet Port
Per Unit Main Channels No.8

2.2Size and Weight

Dimensions9U,485*506*377.6(mm)

2.3Equipment Working Environment

Working Temperature Range0°C–50°C
Storage Temperature Range-10°C–85°C
Working Environment Relative Humidity Range30%–80%RH
Storage Environment Relative Humidity Range30%–90%RH

3,Similar Type
1.BTS-15V6A
Per Unit Main Channels No.:8
Current Output Range:+/-6A
Current measurement Accuracy:0~15V
Power:720W
volume :6U,508*485*263.6(mm)
Material code:CT-3008W-15V6A


2.BTS-20V6A
Per Unit Main Channels No:8
Current Output Range:+/-6A
Current measurement Accuracy:0~20V
Power:960W
volume:6U,508*485*263.6(mm)
item code:CT-3008W-20V6A

Samples test be always welcome!

Meanwhile, we offer other materials for lithium ion battery, such as: LTO, LiCoO2, LiFePO4, LiMn2O4, LiNiMnCoO2, MCMB, separator, al foil, etc.

Otherwise, we also can help customers establish the laboratory and prodcution line for lithium ion battery

Any inquiry, please feel free to contact with me;

lucinda at battery-materials.cn

lucinda at libgroup.net

BTS-5V20A battery testing machine suppliers    BTS-5V20A battery testing machine manufacturers