Kinematic viscometer
Digital temperature control,easy to operate
continuously adjustable accuracy
GB/T 265
North Dalian
Port: Dalian port or other port
Minimum Order Quantity: 1 Set/Sets Discussible
Supply Ability: 300 Set/Sets per Month Discussible
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,Discussible
Contact SupplierPackaging Detail: Treated Wooden PackagingAccording to the request of export.
Delivery Detail: According to your request and the actual situation
BF-03 Tester for the Kinematic Viscosity of Oil(Kinematic viscometer)
1.Technical parameters
Working power | AC 220V ± 10% 50HZ |
Input power | <1850W |
The main heating power | 1000W |
Auxiliary heating power | 800W |
Temperature range | 40 ~ 100 degree |
Temperature accuracy | ± 0.1 degree |
Capillary type | Commodities' capillary viscometer |
Viscometer folder | 4 sets |
2.Applicable standards
BF03 movement is in accordance with Viscosity Determination of GB / T 265 design and manufacturing standards, and can be accurately described in strict accordance with the standards movement of petroleum products for the determination of viscosity.
BF03 movement measuring viscosity of liquid applied to the determination of petroleum products (Newtonian liquid) viscosity of the campaign, the units of mm ² / s.
BF03 viscosity meter movement design beautiful, generous, reasonable structure design, easy to operate, the results of an accurate determination.
3.Apparatus Principle
At a constant temperature, the determination of a certain volume of liquid in the calibration of gravity down a good glass capillary viscometer of the time, the capillary viscometer and the flow time constant of the product, which is the temperature measured the movement of liquid viscosity degrees.
4.Structural characteristics
BF03 Movement viscosity meter table with digital temperature control thermostat bath temperature control, temperature control range of 40 ~ 100 , temperature control accuracy of ± 0.1 . The use of digital temperature control table intuitive display settings temperature and actual temperature, temperature settings and easy to carry out the amendment temperature.
BF03 movement measuring viscosity viscometer equipped with four folders, can be measured in the sample temperature at the same time as other samples to be tested to improve the work efficiency. Cleverly designed viscometer folder, as long as the capillary viscometer viscometer folder can be inserted at the same time regulating viscometer folder location on the three screws will be able to facilitate capillary viscometer adjusted to a vertical position to increase the measured results accuracy.
BF03 campaign Viscosity constant temperature bath for the whole devicetransparent to facilitate the operator to observe the specimen from the perspective of the flow in full compliance with the standard description of the results to improve the accuracy of the determination.
5.Performance characteristics
Digital temperature control, room temperature ~ 100 continuously adjustable, double bathtub, hole, temperature control accuracy of ± 0.1